016-331 Memory Diag Fail-2 RAP

BSD-ON:
BSD 16.1 - ESS
Cont SystemMemory Diag Fail-2. Capacity of Slot2 loaded memory is out of spec.
Procedure
Power Off/On.
Check the sw version of the controller sw - update if required
Remove/insert ESS RAM DIMM.
Replace ESS RAM DIMM
(PL
35.2).
Replace ESS PWB
(PL
35.2).
Status Indicator RAPs
016-331 Memory Diag Fail-2 RAP, 016-332 Memory
016-332 Memory Diag Fail-3 RAP
BSD-ON:
BSD 16.1 - ESS
Cont SystemMemory Diag Fail-3. Capacity of Slot3 loaded memory is out of spec.
Procedure
Power Off/On.
Check the sw version of the controller sw - update if required
Remove/insert ESS RAM DIMM.
Replace ESS RAM DIMM
Replace ESS PWB
07/2011
2-158
BUS Updated 12/2011
(PL
35.2).
(PL
35.2).
WorkCentre 5335 Family Service Documentation
Initial Issue