016-374 Cont Hdd Filesystem Fail-C Rap; 016-375 Cont Hdd Filesystem Fail-D Rap - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

016-374 Cont HDD FileSystem Fail-C RAP

BSD-ON:
BSD 16.1 - ESS
Boot Diag detected a logic error with HDD (Partition C).
Procedure
Perform the following:
1.
Power OFF then ON.
2.
Initialize the HDD
Initialize Hard
Initial Issue
WorkCentre 5335 Family Service Documentation
Disk.
BUS Updated 12/2011

016-375 Cont HDD FileSystem Fail-D RAP

BSD-ON:
BSD 16.1 - ESS
Boot Diag detected a logic error with HDD (Partition D).
Procedure
Perform the following:
1.
Power OFF then ON.
2.
Initialize the HDD
Initialize Hard
07/2011
2-171
Disk.
Status Indicator RAPs
016-374, 016-375

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5335 series

Table of Contents