016-367 Cont HDD Fail-2 RAP

BSD-ON:
BSD 16.1 - ESS
Cont HDD Diagnostic Fail-2. An error occurred during W/R/V test of HDD.
Procedure
Turn the power OFF then ON. If the problem persists, perform the following:
Disconnect and re-connect the HDD Wire Harness
Check for 5VDC between P/J302-1 (red) and P/J302-3 (blk) on the HDD.
Check the sw version of the controller sw - update if required
Replace the HDD and the HDD Wire Harness
Replace the ESS PWB
(PL
35.2).
Status Indicator RAPs
016-367, 016-368
(PL
35.2).
(PL
35.2).
07/2011
BUS Updated 12/2011
016-368 Cont Thumbnail Fail RAP
BSD-ON:
BSD 16.1 - ESS
Cont Diagnostic Fail. An error occurred during W/R/V test of PCI Config interval or W/R/V test
of internal register.
Procedure
NOTE:
Turn the power OFF then ON. If the problem persists, perform the following
Replace the ESS PWB
(PL
35.2). Check the sw version of the controller sw - update if
required.