016-315 IIT Interface RAP
BSD-ON:
BSD 16.1 - ESS
An error was detected in the IF between the IIT and the IOT.
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the IF between Scanner and IOT, IIT, ESS, MCU all PWBs
connected to them (RAM, Firmware module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB
(PL
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB and RAM
DIMM.)
•
Replace the IIT PWB
(PL
1.6). If the problem persists, replace the MCU PWB
Status Indicator RAPs
016-315, 016-316
35.2)
(PL
BUS Updated 12/2011
016-316 Page Memory Not Detected RAP
BSD-ON:
BSD 16.1 - ESS
The system detected that the Page Memory (Standard) of the scanner was not installed.
Initial Actions
Power Off/On
Procedure
•
Ensure connectors on the ESS PWB
connected.
•
Check the installation of the Printer PWB if present.
18.2).
07/2011
2-152
(PL
35.2) and the IIT PWB
(PL
1.6) are securely
Initial Issue
WorkCentre 5335 Family Service Documentation