013-210 Booklet Staple Move Home Sensor ON RAP (LX)
BSD-ON:
BSD 12.25 - Office Finisher Booklet Staple Positioning
Booklet Staple Move Home Sensor does not turn on within designated time period
Initial Actions
•
Ensure the Staple Head is free from obstructions
•
Check for 013-306 or 013-307 Faults.
Procedure
Execute
Component Control
[013-143], Booklet Staple Move Home Sensor. Move the Booklet
Staplers to block and unblock the sensor
(PL
Y
N
Check the wire between
J8897
pin 2 and
loose or damaged connector. The wire is OK.
Y
N
Repair/reconnect as required.
Measure the voltage between P/J8991, pins 3 and 1 on the Booklet PWB. The voltage
is approx. +5VDC.
Y
N
Replace the Booklet PWB
(PL
23.21).
Measure the voltage between
P/J8991
Booklet Staple Move Home Sensor. The voltage changes.
Y
N
Replace the Booklet Staple Move Home Sensor
Replace the Booklet PWB
(PL
23.21).
Alternately execute
Component Control
[013-028], Stapler Move Motor In and [013-029], Sta-
pler Move Motor Out. The Stapler Move Motor moves.
Y
N
Check the wires between
P/J8992
pins 1~6 on the Booklet PWB and
Booklet Stapler Move Motor for an open or short circuit, or loose or damaged connectors.
The wires are OK.
Y
N
Repair/replace as required.
Monitor the voltage at J8984, pin 3. Alternately execute
Stapler Move Motor In and [013-029], Stapler Move Motor Out. An AC clock pulse is
detected.
Y
N
Check the wire between J8984, pin 3 and
Finisher PWB
(PL
23.16).
Replace the Booklet Stapler Move Motor
Booklet PWB
(PL
23.21).
A
Initial Issue
WorkCentre 5335 Family Service Documentation
23.18). The display changes.
P/J8991
pin 2 for an open or short circuit, or a
pin 2 on the Booklet PWB and GND. Actuate the
(PL
23.18).
P/J8906
Component Control
[013-028],
J8985
pin 4. If the wire is OK, replace the
(PL
23.18). If the problem persists, replace the
BUS Updated 12/2011
A
Go to
BSD 12.25 - Office Finisher Booklet Staple
circuit.
on the
07/2011
2-135
Positioning5 and check for an intermittent
Status Indicator RAPs
013-210