ST STM32F101 series Reference Manual page 242

Advanced arm-based 32-bit mcus
Hide thumbs Also See for STM32F101 series:
Table of Contents

Advertisement

RM0008
Bit 2 CAL: A/D Calibration
This bit is set by software to start the calibration. It is reset by hardware after calibration is
complete.
0: Calibration completed
1: Enable calibration
Bit 1 CONT: Continuous conversion
This bit is set and cleared by software. If set conversion takes place continuously till this bit is
reset.
0: Single conversion mode
1: Continuous conversion mode
Bit 0 ADON: A/D converter ON / OFF
This bit is set and cleared by software. If this bit holds a value of zero and a 1 is written to it
then it wakes up the ADC from Power Down state.
Conversion starts when this bit holds a value of 1 and a 1 is written to it. The application
should allow a delay of t
0: Disable ADC conversion/calibration and go to power down mode.
1: Enable ADC and to start conversion
Note: If any other bit in this register apart from ADON is changed at the same time, then
STAB
conversion is not triggered. This is to prevent triggering an erroneous conversion.
DocID13902 Rev 15
Analog-to-digital converter (ADC)
between power up and start of conversion. Refer to
Figure 23.
242/1128
252

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STM32F101 series and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Stm32f107 seriesStm32f102 seriesStm32f103 seriesStm32f105 seriesStm32f101 series

Table of Contents