Encoder Interface Mode - ST STM32F101 series Reference Manual

Advanced arm-based 32-bit mcus
Hide thumbs Also See for STM32F101 series:
Table of Contents

Advertisement

RM0008
The OPM waveform is defined by writing the compare registers (taking into account the
clock frequency and the counter prescaler).
The t
The t
value (TIMx_ARR - TIMx_CCR1).
Let's say you want to build a waveform with a transition from '0' to '1' when a compare
match occurs and a transition from '1' to '0' when the counter reaches the auto-reload
value. To do this you enable PWM mode 2 by writing OC1M=111 in the TIMx_CCMR1
register. You can optionally enable the preload registers by writing OC1PE='1' in the
TIMx_CCMR1 register and ARPE in the TIMx_CR1 register. In this case you have to
write the compare value in the TIMx_CCR1 register, the auto-reload value in the
TIMx_ARR register, generate an update by setting the UG bit and wait for external
trigger event on TI2. CC1P is written to '0' in this example.
In our example, the DIR and CMS bits in the TIMx_CR1 register should be low.
You only want 1 pulse (Single mode), so you write '1 in the OPM bit in the TIMx_CR1
register to stop the counter at the next update event (when the counter rolls over from the
auto-reload value back to 0). When OPM bit in the TIMx_CR1 register is set to '0', so the
Repetitive Mode is selected.
Particular case: OCx fast enable:
In One-pulse mode, the edge detection on TIx input set the CEN bit which enables the
counter. Then the comparison between the counter and the compare value makes the
output toggle. But several clock cycles are needed for these operations and it limits the
minimum delay t
If you want to output a waveform with the minimum delay, you can set the OCxFE bit in the
TIMx_CCMRx register. Then OCxRef (and OCx) are forced in response to the stimulus,
without taking in account the comparison. Its new level is the same as if a compare match
had occurred. OCxFE acts only if the channel is configured in PWM1 or PWM2 mode.
14.3.16

Encoder interface mode

To select Encoder Interface mode write SMS='001' in the TIMx_SMCR register if the
counter is counting on TI2 edges only, SMS='010' if it is counting on TI1 edges only and
SMS='011' if it is counting on both TI1 and TI2 edges.
Select the TI1 and TI2 polarity by programming the CC1P and CC2P bits in the TIMx_CCER
register. When needed, you can program the input filter as well.
The two inputs TI1 and TI2 are used to interface to an incremental encoder. Refer to
Table
81. The counter is clocked by each valid transition on TI1FP1 or TI2FP2 (TI1 and TI2
after input filter and polarity selection, TI1FP1=TI1 if not filtered and not inverted,
TI2FP2=TI2 if not filtered and not inverted) assuming that it is enabled (CEN bit in
TIMx_CR1 register written to '1'). The sequence of transitions of the two inputs is evaluated
and generates count pulses as well as the direction signal. Depending on the sequence the
counter counts up or down, the DIR bit in the TIMx_CR1 register is modified by hardware
accordingly. The DIR bit is calculated at each transition on any input (TI1 or TI2), whatever
the counter is counting on TI1 only, TI2 only or both TI1 and TI2.
Encoder interface mode acts simply as an external clock with direction selection. This
means that the counter just counts continuously between 0 and the auto-reload value in the
TIMx_ARR register (0 to ARR or ARR down to 0 depending on the direction). So you must
configure TIMx_ARR before starting. in the same way, the capture, compare, prescaler,
is defined by the value written in the TIMx_CCR1 register.
DELAY
is defined by the difference between the auto-reload value and the compare
PULSE
min we can get.
DELAY
DocID13902 Rev 15
Advanced-control timers (TIM1&TIM8)
324/1128
359

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stm32f107 seriesStm32f102 seriesStm32f103 seriesStm32f105 seriesStm32f101 series

Table of Contents