output definitions (continued)
Certify/Restore Status
Flash Between CMMs
NIs Reload On Takeover
Stacks Reload on Takeover
Release History
Release 6.6.1; command was introduced.
Related Commands
reload
write memory
copy flash-synchro
MIB Objects
chasControlModuleTable
chasControlRunningVersion
chasControlActivateTimeout
chasControlVersionMngt
chasControlDelayedActivateTimer
chasControlCertifyStatus
chasControlSynchronizationStatus
page 1-16
Indicates if the CM has been certified (i.e., the Working directory
matches the Certified directory).
Displays whether the Working and Certified directories are the same.
Displays how many Network Interface (NI) modules or switches in a
stack will be reloaded in the event of a management module takeover.
Options include NONE, ALL, or a list of specific NIs.
If there are no unsaved configuration changes and the flash directories
on both the primary and secondary management modules have been
synchronized via the
copy flash-synchro
reloaded if a management module takeover occurs. As a result, data
flow is not interrupted on the NIs during the takeover.
If a configuration change is made to one or more NI modules (e.g., a
VLAN is configured on several different interfaces), and the changes
are not saved via the
write memory
will automatically reload if a management module takeover occurs.
Data flow on the affected NIs will be interrupted until the reload is
complete. Note that the NIs will reload whether or not the flash syn-
chronization status shows SYNCHRONIZED. This is because the
unsaved changes have occurred in the running configuration
(i.e., RAM), and have not been written to the flash directory's configu-
ration file. In this case, a list of only the affected NIs displays in the
table output (e.g., 1 6 9 12).
If the flash directories on the primary and secondary management mod-
ules are not synchronized (e.g., a
been issued recently), all NIs will be reloaded automatically if a man-
agement module takeover occurs. Data flow will be interrupted on all
NIs until the reload is complete.
Reboots the CMM to its startup software configuration.
Copies the running configuration (RAM) to the working directory.
Copies the certified directory version of the primary CMM software to
the certified directory of the secondary CMM.