Efm-Oam Errored-Frame - Alcatel-Lucent OmniSwitch 6250 Cli Reference Manual

Hide thumbs Also See for OmniSwitch 6250:
Table of Contents

Advertisement

LINK OAM Commands

efm-oam errored-frame

Configures an error frame threshold or window on a LINK OAM port and set notification status for
errored frame events. When the number of frame errors exceeds a threshold within a given window
defined by a period of time (for example, 10 frames in 1 second had errors), an Errored Frame Event is
generated.
efm-oam port slot/port[-port2] errored-frame [threshold threshold_symbols] [window
window_seconds] [notify {enable | disable}]
Syntax Definitions
slot/port
-port2
threshold_symbols
window_seconds
enable
disable
Defaults
parameter
threshold_symbols
window_seconds
enable | disable
Platforms Supported
OmniSwitch 6250.
Usage Guidelines
The various options, threshold, window and notify can be issued in any order. However, at least one
option has to be entered.
To enter many ports in a single command, use a hyphen to specify a range of ports (e.g. 3/1-16).
Examples
-> efm-oam port 1/1 errored-frame threshold 10 window 32 notify enable
-> efm-oam port 1/1 errored-frame notify disable
-> efm-oam port 2/1-4 errored-frame threshold 10 window 32 notify enable
-> efm-oam port 2/1-2 errored-frame notify disable
OmniSwitch 6250 CLI Reference Guide
The slot number for the module and the physical port number on that
module (e.g. 3/1 specifies port 1 on slot 3).
The last port number in a range of ports that you want to configure on
the same slot (e.g 3/1-4 specifies ports 1,2,3, and 4 on slot 3).
Specifies the frame error threshold number.
Specifies the window of time, in which the frame errors will be
measured. The duration should be in units of 100ms.
Enables notification of the Errored Frame event.
Disables notification of the Errored Frame event.
default
1 frame error
1 second (10 dsec)
enable
November 2009