Bridge Port Pvst - Alcatel-Lucent OmniSwitch 6250 Cli Reference Manual

Hide thumbs Also See for OmniSwitch 6250:
Table of Contents

Advertisement

bridge port pvst+

Configures the type of BPDU to be used on a port when PVST+ mode is enabled.
bridge port {slot/port | agg_num} pvst+ {auto | enable | disable}
Syntax Definitions
slot/port
agg_num
auto
enable
disable
Defaults
parameters
auto | enable | disable
Platforms Supported
OmniSwitch 6250
Usage Guidelines
In order to handle PVST+ mode, the ports must be configured in 1x1 mode.
Initially, a port sends or receive IEEE BPDUs. Once a PVST+ BPDU is received, the port will send
and receive only PVST+ BPDUs for tagged VLANs and IEEE BPDUs for default VLANs.
Examples
-> bridge port 1/3 pvst+ enable
-> bridge port 2/2 pvst+ auto
Release History
Release 6.3.1; command was introduced.
page 16-174
The slot number for the module and the physical port number on that
module (e.g., 3/1 specifies port 1 on slot 3).
Specifies the aggregate group.
IEEE BPDUs are used until a PVST+ BPDU is detected.
Specifies that PVST+ BPDUs will be used.
Specifies that IEEE BPDUs will be used.
default
auto
OmniSwitch 6250 CLI Reference Guide
Distributed Spanning Tree Commands
November 2009