LINK OAM Commands
efm-oam port remote-loopback start
Initiates the loopback control PDU towards the peer port to start or stop the loopback session on the speci-
fied port.
efm-oam port slot/port remote-loopback {start | stop}
Syntax Definitions
slot/port
start
stop
Defaults
N/A
Platforms Supported
OmniSwitch 6250
Usage Guidelines
•
Before issuing this command, the LINK OAM port has to be in active mode and discovery of peer
ports has to be completed.
•
When loopback is started from a port towards a peer port which is configured to ignore the loopback
request, the loopback response timer will timeout and no error is displayed. In such case, verify the
loopback-state of two ports by using the command
•
The maximum number of simultaneous loopback sessions supported per network interface is 2. If a
third loopback is started through CLI, an error will be displayed at the CLI prompt.
Examples
-> efm-oam port 1/1 remote-loopback start
-> efm-oam port 1/1 remote-loopback stop
Release History
Release 6.6.1; command was introduced.
OmniSwitch 6250 CLI Reference Guide
The slot number for the module and the physical port number on that
module (e.g. 3/1 specifies port 1 on slot 3).
Specifies whether to start the loopback request.
Specifies whether to stop the loopback request.
show efm-oam port remote
November 2009
detail.