Alcatel-Lucent OmniSwitch 6250 Cli Reference Manual page 143

Hide thumbs Also See for OmniSwitch 6250:
Table of Contents

Advertisement

Network Time Protocol Commands
Use the version keyword to set the correct version of NTP.
Use the minpoll keyword to set the minimum poll time for the server. This number is determined by
raising 2 to the power of the number entered. Therefore, if 4 were entered, the minimum poll time
would be 16 seconds (2
is exceeded.
Examples
-> ntp server 1.1.1.1
-> ntp server spartacus
-> ntp server 1.1.1.1 key 1
-> ntp server 1.1.1.1 version 4
-> ntp server spartacus minpoll 5
-> no ntp server 1.1.1.1
Release History
Release 6.6.1; command was introduced.
Related Commands
ntp client
MIB Objects
alaNtpConfig
alaNtpPeerAddressType
alaNtpPeerType
alaNtpPeerAuth
alaNtpPeerVersion
alaNtpPeerMinpoll
alaNtpPeerPrefer
alaNtpPeerAddress
OmniSwitch 6250 CLI Reference Guide
4
= 16). The client will poll the server for a time update when the minpoll time
Enables or disables NTP operation on the switch.
November 2009
page 5-3