Show Stack Status - Alcatel-Lucent OmniSwitch 6250 Cli Reference Manual

Hide thumbs Also See for OmniSwitch 6250:
Table of Contents

Advertisement

show stack status

Displays the current redundant stacking cable status and token availability for a stacked configuration.
show stack status
Syntax Definitions
N/A
Defaults
N/A
Platforms Supported
OmniSwitch 6250
Usage Guidelines
N/A
Examples
-> show stack status
Redundant cable status
output definitions
Redundant cable status
Release History
Release 6.6.1; command was introduced.
Related Commands
show stack topology
MIB Objects
alaStackMgrStackStatus
alaStackMgrTokensUsed
alaStackMgrTokensAvailable
page 2-56
: present
Indicates whether a redundant stacking cable is currently installed.
Options include present and not present. To provide added resiliency
and redundancy, it is strongly recommended that a redundant stacking
cable is connected from the top switch in the stack to the bottom switch
in the stack at all times. For more information on stack redundancy,
refer to the "Managing OmniSwitch 6250 Series Stacks" chapter in the
OmniSwitch 6250 Series Hardware Users Guide.
Displays the current operating topology of switches within a stack.
OmniSwitch 6250 CLI Reference Guide
Chassis Management and Monitoring Commands
November 2009