Alcatel-Lucent OmniSwitch 6250 Cli Reference Manual page 106

Hide thumbs Also See for OmniSwitch 6250:
Table of Contents

Advertisement

output definitions (continued)
State
Saved Slot
Link A State
Link A Remote NI
Link A Remote Port
Link B State
Link B Remote NI
Link B Remote Port
Release History
Release 6.6.1; command was introduced.
page 2-54
Chassis Management and Monitoring Commands
The current operational state of the corresponding switch. Options
include RUNNING (the switch is up and operating normally),
DUP-SLOT (the switch has a duplicate saved slot number and has auto-
matically entered pass-through mode), CLR-SLOT (the switch has
been manually "cleared" via the
in pass-through mode), OUT-SLOT (the current stacked configuration
already has eight switches and therefore cannot accommodate this
switch), OUT-TOK (there are not enough unused tokens remaining in
the current stacked configuration to accommodate this switch),
UNKNOWN (the switch's current state is not known).
The designated saved slot number for the corresponding switch. The
saved slot number is the slot position the switch will assume following
a reboot. A value of zero (0) indicates that the switch has been
"cleared" and, as a result, is designated for pass-through mode. To
assign saved slot numbers, use the
switch and designate it for pass-though mode, use the
command.
The current status of the stacking cable link at the switch's stacking
port A. Options include UP, DOWN, or UNKNOWN.
The slot number of the switch to which stacking cable A's remote end is
connected. In other words, if a switch in slot position 1 displays a
Link A Remote NI value of 3, this indicates that the stacking cable
plugged into slot 1 stacking port A is connected to the slot 3 switch. If
no stacking cable link exists, the value 0 displays.
The specific stacking port to which stacking cable A's remote end is
connected. Options include StackA, StackB, and 0. If stacking cable A's
remote end is connected to stacking port B on the other switch, the
value displays StackB. If no stacking cable link exists, the value 0
displays.
The current status of the stacking cable link at the switch's stacking
port B. Options include UP, DOWN, or UNKNOWN.
The slot number of the switch to which stacking cable B's remote end is
connected. In other words, if a switch in slot position 6 displays a
Link A Remote NI value of 7, this indicates that the stacking cable
plugged into slot 6 stacking port B is connected to the slot 7 switch.
The specific stacking port to which stacking cable B's remote end is
connected. Options include StackA, StackB, and 0. If stacking cable
B's remote end is connected to stacking port B on the other switch, the
value displays StackB. If no stacking cable link exists, the value 0
displays.
OmniSwitch 6250 CLI Reference Guide
stack clear slot
command and is now
stack set slot
command. To clear a
stack clear slot
November 2009

Advertisement

Table of Contents
loading

Table of Contents