command-log

Enables or disables command logging on the switch. When command logging is enabled, a command.log
is automatically created; this file stores a comprehensive CLI command history for all active sessions since
the function was first enabled.
command-log {enable | disable}
Syntax Definitions
enable
disable
Defaults
parameter
enable | disable
Platforms Supported
OmniSwitch 6250
Usage Guidelines
The maximum log file size is 66,402 bytes; the file may hold up to 100 commands.
Examples
-> command-log enable
-> command-log disable
Release History
Release 6.6.1; command was introduced.
Related Commands
show ssh config
show command-log status
MIB Objects
sessionCliCommandLogEnable
page 6-24
Creates a file called command.log in the switch's /flash directory. Any
configuration commands entered on the command line will be recorded
to this file until command logging is disabled.
Disables logging of current session commands to the command.log file.
default
disable
Displays the contents of the command.log file.
Shows the current status of the command logging function
(i.e., enabled or disabled).