lldp notification interval

Sets the time interval that must elapse before a notification about the local system MIB change is
generated.
lldp notification interval seconds
Syntax Definitions
seconds
Defaults
parameter
seconds
Platforms Supported
OmniSwitch 6250
Usage Guidelines
The LLDP protocol and notification must be enabled before using this command.
In a specified interval, generating more than one notification-event is not possible.
Examples
-> lldp notification interval 25
Release History
Release 6.6.1; command was introduced.
Related Commands
lldp notification
show lldp local -system
MIB Objects
lldpConfiguration
lldpNotificationInterval
page 13-6
The minimum number of seconds for generating a notification-event.
The valid range is 5-3600.
default
5
Specifies the switch to control per port notification status about the
remote device change.
Displays local system information.