Control Block Diagram For Phase Control - YASKAWA JEPMC-MP2300-Y Series User Manual

Machine controller basic module
Table of Contents

Advertisement

8 Control Block Diagrams

8.2.2 Control Block Diagram for Phase Control

8.2.2 Control Block Diagram for Phase Control
OW
00 Run Commands
OW
03 Function 1
OW
05 Function 3
OW
08 Motion Command
OW
09 Motion Command Options
OW
0A Motion Subcommand
OL
10 Speed Reference
OL
1E Positioning Completed Width
OL
20 Positioning Completed Width 2
OL
22 Deviation Abnormal Detection Value
OW
26 Positioning Complete Timeout
OL
28 Speed Reference
OL
28 Phase Compensation
OW
31 Speed Amends
OL
16 Secondly Speed Compensation
OW
3A Filter Time Constant
OL
48 Zero Point Offset
OL
4A Work Coordinate System Offset
OL
4C Preset Data of POSMAX Turn
IW
00 Drive Status
IL
02 Warning
IL
04 Alarm
IW
08 Servo Command Type Response
IW
09 Servo Module Command Status
IW
0A Motion Subcommand Response Code
IW
0B Motion Subcommand Status
IW
0C
Position Management Status
IL
0E
Machine Coordinate Target Position (TPOS)
IL
10
Target Position (CPOS)
IL
12
Machine Coordinate System Position (MPOS)
IL
14
32-bit Coordinate System Position (DPOS)
IL
16
Machine Coordinate Feedback Position (APOS)
IL
18
Machine Coordinate Latch Position (LPOS)
IL
1A
Position Error (PERR)
IL
1C
Target Position Difference Monitor
IL
1E
POSMAX Number of Turns
IL
20
Speed Reference Output Monitor
IW
2C Network Servo Status
IW
2D
Servo Alarm Code
IW
2E
Network Servo I/O Monitor
IW
2F
Network Servo User Monitor Information
IW
30
Servo User Monitor 2
IL
40 Feedback Speed
IL
42 Torque (Thrust) Reference Monitor
8-8
Move command generation processing
(When using an electronic shaft)
Target
Target position
+
+
position
difference
operation
operation
(Integration)
+
Unit change
Difference
[UNIT]
operation
[pulse]
Move command generation processing
(When using an electronic cam)
Unit change
[UNIT]
ON
[pulse]
OFF
Unit change
Target
Difference
+
[UNIT]
position
operation
operation
[pulse]
(Integration)
Speed reference
unit change
Speed reference
unit change
Speed reference
unit change
POSMAX processing
Unit change
POSMAX processing
Unit change
POSMAX processing
Unit change
Move command
generation
invalid
(OW
05.Bit1)
OFF
ON
Phase
compensation
type
(OW
09.Bit6)
+
+
+
[pulse]
[UNIT]
[pulse]
[UNIT]
+
[pulse]
[UNIT]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp2300

Table of Contents