YASKAWA JEPMC-MP2300-Y Series User Manual page 341

Machine controller basic module
Table of Contents

Advertisement

( 5 ) Motion Command Response Codes
IW
08
R
Motion Command Response Codes
Stores the motion command code for the command that is currently being executed.
This is the motion command code that is currently being executed and is not necessarily the same as the Motion
Command (setting parameter OW
Response codes are also stored when the following processing is executed.
Description
 ・ Servo ON: 29
 ・ Servo OFF: 30
 ・ Clear alarms: 31
( 6 ) Motion Command Status
IW
09
Servo Module Command Status
Command Executing (BUSY)
 OFF: READY (completed)
 ON: BUSY (processing)
Bit 0
This bit indicates the motion command status. Refer to Chapter 7 Motion Commands for details on command
timing charts.
This bit turns ON during execution of commands that have been completed or during abort processing.
Command Hold Completed (HOLDL)
 OFF: Command hold processing not completed
Bit 1
 ON: Command hold completed
This bit turns ON when command hold processing has been completed. Refer to Chapter 7 Motion Commands
for details on command timing charts.
Command Error Occurrence (FAIL)
 OFF: Normal completion
 ON: Abnormal completion
Description
Bit 3
This bit turns ON if motion command processing does not complete normally.
If motion command execution ends in an error, the axis will stop any motion. Refer to Chapter 7 Motion Com-
mands for details on command timing charts.
Reset Absolute Encoder Completed
 OFF: Reset not completed
 ON: Reset completed
Bit 7
This bit turns ON when the Reset Absolute Encoder command (ABS_RST) is executed and initialization is
completed.
Refer to Chapter 7 Motion Commands for details on command timing charts.
Command Execution Completed (COMPLETE)
 OFF: Normal execution not completed
Bit 8
 ON: Normal execution completed
This bit turns ON when motion command processing was completed normally. Refer to Chapter 7 Motion
Commands for details on command timing charts.
( 7 ) Motion Subcommand Response Code
IW
0A
R
Motion Subcommand Response Code
Stores the motion subcommand code for the command that is being executed.
This is the motion subcommand code that is currently being executed and is not necessarily the same as the Motion
Description
Subcommand (setting parameter OW
Subcommands are used by the system for latch commands and reading/writing parameters.
Setting Range
08).
Setting Range
R
R
R
R
Setting Range
0A).
6.4 MP2300 Parameter Details
Setting Unit
0 to 65535
Setting Unit
Setting Unit
0 to 65535
6-51