[ b ] Communication Specifications
RS-232C Communication Specifications.
Item
Connectors
Transmission Distance
Baud Rate
Access Mode
Communication Modes
Communication Protocols
Media Access Control
Method
Transmission Format
(Can be set)
PROFIBUS Communication Specifications
Item
Mounted Functions
Baud Rate
Configuration
Slave Address
I/O Processing
Diagnostic Functions
* 1. The PROFIBUS ID is 05C1.
* 2. The PROFIBUS ID can be set between 0 and 125 but the 261IF-01 Module can be
9-pin D-sub (female)
15 m max.
9,600 or 19,200 bps
Asynchronous (start-stop synchronization)
Message communication, engineering communication
MEMOBUS, MELSEC, OMRON, Non-procedure
1:1
Data length: 7 or 8 bits
Stop bits: 1 or 2 bits
Parity: Odd, even, or none
DP slave function
• Cyclic communication (DP standard function)
12 M/6 M/4 M/3 M/1.5 M/750 k/500 k/187.5 k/93.75 k/19.2 k/9.6 kbps
(Auto detect)
Implemented by the PROFIBUS Master
*2
1 to 64
• Total I/O register area: Max. 122 words
• I/O allocations: Max. 61 words each
• Status and slave status display using MPE720
• I/O error display using system register
The GSD file YASK05C1.GSD is provided for master configuration.
GSD file: Defines slave information.
set between 1 and 64.