7 Motion Commands

7.2.13 Change Speed Loop Gain (KVS)

7.2.13 Change Speed Loop Gain (KVS)
( 1 ) Executing/Operating Procedure
No.
1
2
( 2 ) Holding and Aborting
( 3 ) Related Parameters
[ a ] Setting Parameters
Parameter
OW
08
Motion Command
OB
090
Command Pause
OB
091
Command Abort
OW
2F
Speed Loop Gain
7-62
The KVS command transfers the setting of the Speed Loop Gain (motion setting parameter
OW
2F) to the Speed Loop Gain in the SERVOPACK and enables the setting.
MECHATROLINK-II has a function that automatically updates setting parameters if a parameter
changes. There is no need to execute the KVS command with this function. For details, refer to bit
A (User Constants Self-Writing Function) in 6.4.1 ( 2 ) Function Selection 1 on page 6-18.
1.
Check to see if all the following conditions are satisfied.
Execution Conditions
There are no alarms.
Motion command execution has been completed.
2.
Set OW
08 to 14 to execute the KVS motion command.
The KVS command will transfer the setting of the Speed Loop Gain (motion setting parameter
OW
2F) to the Speed Loop Gain in the SERVOPACK and enables the setting.
IW
08 will be 14 during command execution.
IB
090 will turn ON during the command processing and will turn OFF when the command
processing has been completed.
3.
Set OW
08 to 0 to execute the NOP motion command and then complete the
change of the speed loop gain.
The Command Pause bit (OB
Name
The speed loop gain is changed when this parameter is set to 14.
This parameter is ignored for KVS command.
This parameter is ignored for KVS command.
Set the gain for the SERVOPACK speed control loop.
Both IL
IW
08 is 0 and IB
090) and the Command Abort bit (OB
Setting
Confirmation Method
02 and IL
04 are 0.
090 is OFF.
091) cannot be used.