YASKAWA JEPMC-MP2300-Y Series User Manual page 216

Machine controller basic module
Table of Contents

Advertisement

4 Mounting and Wiring
4.4.2 LIO-04/LIO-05 Module Connections
( 8 ) LIO-04 Module Connector Connection Examples
24 VDC
CN1 connector
+ -
pin No.
Com-
mon 1
-
+
1
Input 0
2
Input 1
27
Input 6
5
Input 7
30
24 VDC
+ -
Com-
mon 2
-
+
6
Input 8
7
32
Input 9
Input 14
10
Input 15
35
4-42
■ CN1 Connector Connection Example
JEPMC-IO2303
+5V
Photocoupler
R
5.6 kΩ
R
Photocoupler
R
Fuse blowout
detection circuit
Photocoupler
R
Fuse blowout
detection circuit
Check the polarity of the external power supply when wiring. An adverse connection may cause a
load malfunction.
The pins No. 39 and 43 and the pins No. 46 and 50 are internally connected. Connect them exter-
nally as well.
24 VDC
15
+ -
12
Output 1
L
Output 2
37
L
13
Output 3
L
38
Output 4
L
16
Output 5
L
Output 6
41
L
17
Output 7
L
42
Output 8
L
43
39
24 VDC
22
+ -
Output 9
19
L
44
Output 10
L
20
Output 11
L
Output 12
45
L
Output 13
23
L
Output 14
48
L
Output 15
24
L
Output 16
49
L
50
46

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp2300

Table of Contents