YASKAWA JEPMC-MP2300-Y Series User Manual page 571

Machine controller basic module
Table of Contents

Advertisement

Name
Servo Alarm
Code (cont'd)
[ c ] Σ-III Series
Name
Servo Alarm
Code
Register
Code
Number
E2
Option WDC Error
E5
WDT Error
E6
Communication Error
E7
Application Module Detection Failure
E9
Bus OFF Error
EA
SERVOPACK Failure
IW
2D
EB
SERVOPACK Initial Access Error
(cont'd)
EC
SERVOPACK WDC Error
ED
Command Execution Not Completed
EF
Application Module Alarm
F1
Broken Phase in Power Line
F5
Motor Wire Disconnection (when control power supply is turned ON)
F6
Motor Wire Disconnection (when Servo is ON)
Register
Code
Number
000
Normal
900
Excessive Position Error
901
Excessive Position Error at Servo ON
910
Overload
911
Vibration
920
Regeneration Overload
930
Absolute Encoder Battery Error
941
Parameter Change Requiring Power Recycling
94A
Data Setting Warning 1 (Parameter Number)
94B
Data Setting Warning 2 (Outside Data Range)
94C
Data Setting Warning 3 (Calculation Error)
94D
Data Setting Warning 4 (Parameter Size)
95A
Command Warning 1 (Command Conditions Not Met)
95B
Command Warning 2 (Unsupported Command)
95C
Command Warning 3
IW
2D
95D
Command Warning 4
95E
Command Warning 5
960
MECHATROLINK Communication Warning
020
Parameter Checksum Error 1
021
Parameter Format Error 1
022
System Constant Checksum Error 1
023
Parameter Password Error 1
02A
Parameter Checksum Error 2
02B
System Constant Checksum Error 2
030
Main Circuit Detector Error
Parameter Setting Error 1
040
04A
Parameter Setting Error 2
041
Divided Pulse Output Setting Error
042
Parameter Combination Error
050
Combination Error
051
Unsupported Product Alarm
12.6 Troubleshooting Motion Errors
Meaning
Meaning
12-31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp2300

Table of Contents