11.3.2 Precautions When Saving SERVOPACK Parameters
( 7 ) Saving Data to Flash Memory
MPE720
online
Current
Input
Display
Value
Data
Input
Data
HDD in personal computer
11.3.2 Precautions When Saving SERVOPACK Parameters
11-16
The data flow for SERVOPACK parameters is as follows when saving the parameters to flash
memory on the MPE720:
• The MP2300 writes the parameters data (Input Data) held in SDRAM to flash memory.
System
SRAM
Software
Flash
SDRAM
Memory
Servo Parameters
(All Axes)
MP2300
Save to flash memory also after having changed set data of SERVOPACK parameter.
Before executing saving operation in the SERVOPACK Tab Page in any cases including the SERVO-
PACK replacement, always select Edit - Copy Current Value to copy the values in Current Value to
Input Data.
MECHATROLINK
Send
Control
Software
RAM
Parameters
SERVOPACK
Send
EEP
-ROM
SERVOPACK