Startup Sequence And Basic Operation; Dip Switch Settings - YASKAWA JEPMC-MP2300-Y Series User Manual

Machine controller basic module
Table of Contents

Advertisement

5 Outline of Motion Control Systems

5.1.1 DIP Switch Settings

5.1 Startup Sequence and Basic Operation

5.1.1 DIP Switch Settings
Switch
No.
Name
1
STOP
2
SUP
INIT
3
4
CNFG
5
MON
6
TEST
5-2
This section describes the MP2300 startup sequence and basic operation together with the DIP switch
settings, self-diagnosis at startup, and LED indicator patterns.
Set the DIP switch on the Basic Module to control operations of the startup sequence. The six
switches are provided on the DIP switch on the Basic Module as shown in the figure below. The fol-
lowing table lists the functions of six switches.
Status
Operating Mode
ON
User program stops
OFF
User program operation
ON
System use
OFF
Normal operation
ON
Memory clear
OFF
Normal operation
ON
Configuration mode
OFF
Normal operation
ON
System use
OFF
Normal operation
ON
System use
OFF
Normal operation
STOP
1
SUP
2
INIT
3
CNFG
4
5
MON
SW1
6
TEST
OFF
ON
Default
Setting
Set to ON to stop user program operation and debug the
OFF
program.
OFF
Always use set to OFF.
Set to ON to clear memory.
Programs stored in flash memory will be run when Memory
OFF
Clear is set to OFF.
S and M registers are cleared to all zeros.
OFF
Set to ON for self-configuration of connected devices.
OFF
Always set to OFF.
OFF
Always set to OFF.
Remarks
*1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp2300