Precautions When Setting Or Changing User Definition Files And Scan Times - YASKAWA JEPMC-MP2300-Y Series User Manual

Machine controller basic module
Table of Contents

Advertisement

[ b ] SERVOPACK Parameters (2)
SERVOPACK Parameters
Name
Excessive Position Error
Area
Overflow Level
Excessive Position Error
Alarm Detection Level
Excessive Position Error
Warning Detection Level
11.2 Precautions When Setting or Changing User Definition Files and
Scan Times
11.2.1 Setting or Changing User Definition Files
11.2.2 Setting or Changing Module Configuration Definition Files

11.2 Precautions When Setting or Changing User Definition Files and Scan Times

MP2300
Setting
65535
32767
30
2
-1
100
The above set values are written to the SERVOPACK's RAM.
This section describes precautions for setting or changing user definition files and for setting the scan
times.
User definition files must be saved to flash memory (Save & Save to Flash).
Use the MPE720 to set or change a user definition file. Be sure to save the results to flash memory. If
data is not saved to flash memory, the settings and changes will be lost when the power supply to the
MP2300 is turned OFF and ON.
Observe the following precautions when setting or changing module configuration definition files.
• Always check to make sure that the mounted Module is the one that is defined.
• Be sure to save any new settings or changes to flash memory.
• After the settings or changes have been completed, turn the power supply to the MP2300
OFF and ON.
SERVOPACK
SGD-N,
SGDH +
SGDB-N
NS100
Cn-001E
User Definition Files
SGDH +
SGDS
NS115
Pn505
Pn520
Pn51E
11-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp2300

Table of Contents