7 Motion Commands

7.2.10 Change Linear Deceleration Time Constant (DCC)

7.2.10 Change Linear Deceleration Time Constant (DCC)
( 1 ) Executing/Operating Procedure
No.
1
There are no alarms.
2
Pulse distribution has been completed for the SERVOPACK.
3
Motion command execution has been completed.
( 2 ) Holding and Aborting
( 3 ) Related Parameters
[ a ] Setting Parameters
Parameter
OW
03
Function 1
OW
08
Motion Command
OB
090
Command Pause
OB
091
Command Abort
OL
38
Linear Deceleration Time
7-56
The DCC command transfers the setting of the Linear Deceleration Time (motion setting parameter
OL
38) to the Second-step Linear Deceleration Time Constant in the SERVOPACK and enables
the setting.
For the SGD-
N and SGDB SERVOPACKs, this command cannot be used because these
SERVOPACKs does not have the parameters for setting the deceleration time constant.
MECHATROLINK-II has a function that automatically updates setting parameters if a parameter
changes. There is no need to execute the DCC command with this function. For details, refer to bit
A (User Constants Self-writing Function) in the 6.4.1 ( 2 ) Function Selection 1 on page 6-18.
1.
Check to see if all the following conditions are satisfied.
Execution Conditions
2.
Set OW
08 to 11 to execute the DCC motion command.
The DCC command will transfer the setting of the Linear Deceleration Time (motion setting
parameter OL
38) to the Second-step Linear Deceleration Time Constant in the SERVO-
PACK and enables the setting.
IW
08 will be 11 during command execution.
IB
090 will turn ON during the command processing and will turn OFF when the process-
ing has been completed.
3.
Set OWxx08 to 0 to execute the NOP motion command and then complete the change
of the linear deceleration time constant.
The Command Pause bit (OB
Name
Set the speed unit, acceleration/deceleration unit, and filter type.
The linear deceleration time constant is changed when this parameter is set to 11.
This parameter is ignored for DCC command.
This parameter is ignored for DCC command.
Set the deceleration for feeding as the deceleration time.
Both IL
IB
IW
090) and the Command Abort bit (OB
Setting
Confirmation Method
02 and IL
04 are 0.
0C0 is ON.
08 is 0 and IB
090 is OFF.
091) cannot be used.