YASKAWA JEPMC-MP2300-Y Series User Manual page 404

Machine controller basic module
Table of Contents

Advertisement

7 Motion Commands
7.2.6 JOG Operation (FEED)
[ b ] Monitoring Parameters
Parameter
IB
001
Servo ON
IL
02
Warning
IL
04
Alarm
Servo Command
IW
08
Type Response
Command
IB
090
Executing
Command Hold
IB
091
Completed
IB
093
Command Error End
Command
IB
098
Execution
Completed
Distribution
IB
0C0
Completed
Positioning
IB
0C1
Completed
IB
0C3
Position Proximity
7-46
Name
Indicates the Servo ON status.
ON: Power supplied to Servomotor, OFF: Power not supplied to Servomotor
Stores the most current warning.
Stores the most current alarm.
Indicates the motion command that is being executed.
The response code is 7 during FEED command execution.
Turns ON when abort processing is being performed for FEED command. Turns
OFF when abort processing has been completed.
Always OFF for FEED command.
Turns ON if an error occurs during FEED command execution. The axis will
decelerate to a stop if it is moving. Turns OFF when another command is executed.
Always OFF for FEED command.
Turns ON when pulse distribution has been completed for the move command.
Turns OFF during execution of a move command.
Turns ON when pulse distribution has been completed and the current position is
within the Positioning Completed Width. OFF in all other cases.
The operation depends on the setting of the Positioning Completed Width 2 (setting
parameter OL
OL
20 = 0: Turns ON when pulse distribution has been completed (DEN =
OL
20
Monitor Contents
20).
ON). Otherwise, it turns OFF.
0: Turns ON when the absolute value of the difference between
MPOS and APOS is less than the Position Proximity Setting even
if pulse distribution has not been completed.
OFF in all other cases.
SVR
R
R
R
R
R
R
R
R
R
R
R

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp2300