Page 1
YASKAWA AC Drive V/J1000 External Heatsink Attachment Option Manual Type: CIMR-J Type: CIMR-V To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance. Ensure the end user receives this manual. MANUAL NO. EZZ020568...
Page 2
Yaskawa. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice.
Table of Contents PREFACE AND SAFETY..................4 GENERAL SAFETY....................5 ABOUT THIS OPTION.....................7 EXTERNAL HEATSINK OPTION INSTALLATION PROCEDURE......9 INSTALLATION PROCEDURE BY DRIVE MODEL..........12 EXTERNAL HEATSINK OPTION PART NUMBERS BY DRIVE MODEL.....21 REVISION HISTORY....................23 YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
Yaskawa must be supplied to the end user with appropriate warnings and instructions as to the safe use and operation of that part. Any warnings provided by Yaskawa must be promptly provided to the end user.
• When ordering a new copy of the manual due to damage or loss, contact your Yaskawa representative or the nearest Yaskawa sales office and provide the manual number shown on the front cover.
Page 6
Check all the wiring to ensure that all connections are correct after installing the option and connecting any other devices. Failure to comply could result in damage to the option. YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
Do not allow ice to develop on the drive. Humidity 95% RH or less and free of condensation Storage Temperature -20 °C to +60 °C (-4 °F to +104 °F) YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
Page 8
Place a temporary cover over the top of the drive during installation. Remove the temporary cover before drive start-up, as the cover will reduce ventilation and cause the drive to overheat. YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
CIMR-JoBo0001 to 0010 J1000 CIMR-Jo2o0001 to 0020 CIMR-Jo4o0001 to 0011 Figure 1 CIMR-VoBo0001 to 0018 CIMR-Vo2o0001 to 0020 V1000 CIMR-Vo4o0001 to 0011 CIMR-Vo2o0030 to 0069 Figure 2 CIMR-Vo4o0018 to 0038 YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
Page 13
Figure 4. Reattach the front cover according to the drive instruction manual. M4x13 Pan-head Screws (x4) Attachment B Attachment B Attachment A Figure 3 Procedure 1 Diagram (Example Model: CIMR-Vo2o0001) YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
Page 14
4. Reattach the front cover according to the drive instruction manual. M4 x 10 Pan-head Screws (x4) M4 x 10 Pan-head Screws (x2) Attachment A Attachment A Attachment B Attachment B Figure 4 Procedure 2 Diagram (Example Model: CIMR-Vo4o0001) YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
Page 15
1. Mount the Convective Back Plate to the mounting holes on underside of the heatsink using M4×10 pan-head screws. Convective back plate M4 x 10 Pan-head Screw Figure 6 Procedure 4 Diagram (Example Model: CIMR-Vo2o0010) YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
Page 16
(1.1) (1.2) (2.7) (1.2) Fig. B Fig. D 4-M4 Tap 4-M4 Tap (2-n 5 holes) (2-n 5 holes) (6.2) (3.8) 80 (3.1) 142 (5.6) (1.1) (1.1) (6.6) (4.2) (1.1) (1.1) YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
Page 17
Refer to Figure A, B, C, or D for gasket dimensions for your specific model. Gasket type: CR-Series or EPDM-Series made of foam rubber, approximately 2 mm in thick. Sealant Sealant Figure 7 Sealant Placement YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
Page 18
M5 x 12 Pan-head Screws (x2) (screw size varies by model) M5 x 12 Pan-head Screws (x2) Attachment 2 (screw size varies by model) Figure 9 Diagram shown for Model CIMR-Vo2o0030 Install Attachment 3 YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
Page 19
Install Attachment 3 to the mounting holes of Attachment 1 and Attachment 2 using M4 x10 pan-head screws. M4 x 10 Pan-head Screws (x2) Attachment 3 Figure 10 Attachment 3 Complete the assembly. Install the terminal cover. Figure 11 Completed Assembly YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
Vo4o0038 Screws (×5) <1> Use of this option kit on certain NEMA Type 1 standard drives, requires removal of the drive top cover, NEMA Type 1 cover and conduit bracket. YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
Page 22
6 External Heatsink Option Part Numbers by Drive Model This page intentionally blank YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
Example: MANUAL NO. TM.V1000SW.029 Published in U.S.A. March 2013 13-3 Revision number Date of original Date of publication publication Revision Date of Publication Section Revised Content Number September 2013 First Edition YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
Page 24
7 Revision History This Page Intentionally Blank YASKAWA V1000/J1000 AC Drive External Heatsink Kit Option Manual EZZ020568...
Page 26
YASKAWA AC Drive V/J1000 External Heatsink Attachment Option Manual YASKAWA AMERICA, INC. 2121 Norman Drive South, Waukegan, IL 60085, U.S.A. Phone: (800) YASKAWA (927-5292) or 1-847-887-7000 Fax: 1-847-887-7310 http://www.yaskawa.com DRIVE CENTER (INVERTER PLANT) 2-13-1, Nishimiyaichi, Yukuhashi, Fukuoka, 824-8511, Japan Phone: 81-930-25-3844 Fax: 81-930-25-4369 http://www.yaskawa.co.jp...
Need help?
Do you have a question about the V1000 Series and is the answer not in the manual?