YASKAWA JEPMC-MP2300-Y Series User Manual page 123

Machine controller basic module
Table of Contents

Advertisement

( 2 ) External Appearance, LED Indicators, and Switch Settings
[ a ] External Appearance
The following figure shows the SVB-01 Module external appearance.
[ b ] LED Indicators
The following table shows the SVB-01 Module status when each LED indicator is lit or unlit.
RDY
RUN
ERR
ALM
TRX
BAT
[ c ] Switch Settings
Both the DIP switch and rotary switches set the operating conditions for the SVB-01 Module.
Use the default settings when using the Module in Master Mode.
DIP Switch
SIZE and SPD are valid only in Slave Mode. They will be ignored in Master Mode.
M/S
SIZE
SPD
OFF
ON
Rotary Switches
10
1
LED indicators
DIP switch
Rotary switches
(Station address
setting)
MECHATROLINK
connector
MECHATROLINK
connector
Indicator
Color
RUN
Green
Normal operation
ERR
Red
Failure (lights/blinks)
MECHATROLINK transmission in
TX
Green
progress
Name
Status
ON
OFF
ON
M/S
OFF
ON
SIZE
OFF
ON
SPD
OFF
Name
Status
Local station address when in
×10
0 to 9
Slave Mode (10s digit)
Local station address when in
×1
0 to 9
Slave Mode (1s digit)
SVB-01
RUN
ERR
TX
M/S
SIZE
SPD
OFF
ON
10
1
M-I/II
CN1
CN2
Status When Lit
Default
Operating Mode
Setting
Reserved.
OFF
Reserved.
Slave Mode
OFF
Master Mode
17 bytes
OFF
32 bytes
4 Mbps
OFF
10 Mbps
Operating Mode
3.3 Motion Modules (Optional)
Status When Unlit
Error occurrence
Normal operation
No data being transmitted
Details
Keep turned OFF.
Select Master or Slave Mode.
Select the number of send bytes.
Select the baud rate.
Default
Details
Setting
Sets the 10s digit of the local
0
slave address.
Sets the 1s digit of the local
1
slave address.
3-15