12 Maintenance and Inspection
12.6.2 Motion Error Details and Corrections
( 10 ) Bit 10: Filter Type Change Error
Detection Timing
Processing when
Alarm Occurs
Error and Cause
Correction
( 11 ) Bit 11: Filter Time Constant Change Error
Detection Timing
Processing when
Alarm Occurs
Error and Cause
Correction
( 12 ) Bit 13: Zero Point Not Set
Detection Timing
Processing when
Alarm Occurs
Error and Cause
Correction
( 13 ) Bit 16: Servo Driver Synchronization Communication Error
Detection Timing
Processing when
Alarm Occurs
Error and Cause
Correction
12-26
• Continuously monitored by the motion command processing section.
• The Change Filter Type command will not be executed.
• The Command Error Occurrence in the Servo Module Command Status (IW
• Interpolation Commands (Interpolation or Interpolation with Position Latch)
An error occurs if the Change Filter Type command is executed before the specified pulse distribution has
not been completed (i.e., when IB
• Positioning Commands (Positioning, External Positioning, STEP Operation, or JOG Operation)
The Change Filter Type command will be ignored. (An error will not occur.)
• Correct the program to execute the Change Filter Type command after Distribution Completed status (i.e.,
that IB
0C0 is ON) is checked.
The command running will not stop even if the above error occurs. The stop processing from the
user program is needed to stop running commands when necessary.
• Continuously monitored by the motion command processing section.
• The SCC (Change Filter Time Constant) command will not be executed.
• The Command Error Occurrence in the Servo Module Command Status (IW
• Interpolation Commands (Interpolation or Interpolation with Position Latch)
An error occurs if the SCC command is executed before the specified pulse distribution has not been
completed (i.e., when IB
0C0 was OFF).
• Positioning Commands (Ppositioning, External Positioning, STEP Operation, or JOG Operation)
The Change Filter Time Constant command will be ignored. (An error will not occur.)
• Correct the program to execute the SCC command after Distribution Completed status (i.e., that
IB
0C0 is ON) is checked.
The command running will not stop even if the above error occurs. The stop processing from the
user program is needed to stop running commands when necessary.
• Enabled only when an absolute encoder is used for an infinite length axis and detected when the next
command is set in the Motion Command (OW
 Commands: Positioning, External Positioning, Interpolation, or Latch
• The set command will not be executed.
• The Command Error Occurrence in the Servo Module Command Status (IW
• A move command was set without executing the ZSET command (IW
• After clearing the motion command and resetting the alarm, execute a Zero Point Setting operation.
• Detected by the communication control section when communication are synchronized between the
MP2300 and SERVOPACK.
• The current command will be aborted.
• An error occurred in MECHATROLINK communication (e.g., cable disconnect or noise interference on
communication line).
• Check the MECHATROLINK cable and reset the alarm.
0C0 was OFF).
08).
09 bit 3) will turn ON.
09 bit 3) will turn ON.
09 bit 3) will turn ON.
0C bit 5 is OFF).