8.14 Change Speed Loop Gain (KVS)

The KVS command transfers the setting of the Speed Loop Gain (motion setting parameter OW
Speed Loop Gain in the SERVOPACK and enables the setting.
(1) Operating Procedure
No.
1
There are no alarms.
2
Motion command execution has been completed.
Execute the KVS motion command.
• Set OW
08 to 14.
The Speed Loop Gain is set in the
SERVOPACK and enabled.
• IW
08 will be 14 during command
execution.
• IB
090 will be ON during command
execution.
Parameter change completed.
• IW
08 will be 14 and IB
OFF.
Execute NOP motion command.
• Set OW
08 to 0.
(2) Holding and Aborting
The Command Pause bit (OB
(3) Related Parameters
(a) Setting Parameters
Parameter
OW
08
Motion Command
OB
090
Command Pause
OB
091
Command Abort
OW
2F
Speed Loop Gain
(b) Monitoring Parameters
Parameter
IL
02
Warning
IL
04
Alarm
IW
08
Servo Command
Type Response
IB
090
Command Executing
IB
091
Hold Completed
IB
093
Command Error End
IB
098
Command
Completed
Execution Conditions
090 will be
090) and the Command Abort bit (OB
Name
The speed loop gain is changed when this parameter is set to 14.
This parameter is ignored for KVS command.
This parameter is ignored for KVS command.
Set the gain for the SERVOPACK speed control loop.
Name
Stores the most current warning.
Stores the most current alarm.
Indicates the motion command that is being executed.
The response code will be 14 during KVS command execution.
Turns ON during KVS command execution and turns OFF when execution has
been completed.
Always OFF for KVS command.
Turns ON if an error occurs during KVS command execution. Turns OFF when
another command is executed.
Turns ON when KVS command execution has been completed.
8.14 Change Speed Loop Gain (KVS)
Confirmation Method
Both IL
02 and IL
IW
08 is 0 and IB
• With the MECHATROLINK-II, there is the function that the
change of setting parameter is automatically updated. If utilizing
this function, there is no need to execute KVS command. For
details, refer to 7.2.1 Motion Fixed Parameter Details.
• The Command Pause (OB
• The Command Abort (OB
091) cannot be used.
Setting
Monitor Contents
2F) to the
04 are 0.
090 is OFF.
090) cannot be used.
091) cannot be used.
8