DPR DIFFERENTIAL PRESSURE SENSOR
STANDARD VALUE, LIMIT AND ACTION
Inspection item
Resistance between termi-
nals
TIGHTENING TORQUE
Tightening part
DPR differential pressure sensor mounting nut
SCR UPSTREAM NOx SENSOR
TIGHTENING TORQUE
Tightening part
SCR upstream NOx sensor
Clip mounting nut
SCR upstream NOx controller mounting nut
SCR DOWNSTREAM NOx SENSOR
TIGHTENING TORQUE
Tightening part
SCR downstream NOx sensor
SCR downstream NOx controller mounting nut
ATC DOWNSTREAM TEMPERATURE SENSOR
STANDARD VALUE, LIMIT AND ACTION
Inspection item
Resistance between termi-
nals
TIGHTENING TORQUE
Tightening part
ATC downstream temperature sensor
STANDARD VALUE (J05E)
AB
BC
50 C {122 F}
Standard value
15 k
15 k
Tightening torque
31 {316, 22.9}
Tightening torque
40-60 {408-612, 29.5-44.2}
31 {316, 22.9}
5.5 {56, 4.1}
Tightening torque
40-60 {408-612, 29.5-44.2}
5.5 {56, 4.1}
Standard value
8.0-17.2 k
Tightening torque
25-35 {255-357, 18.4-25.8}
2–27
EN01F02127010701007013
Action
Replace
Replace
Unit: Nm {kgfcm, lbfft}
Remarks
EN01F02127010701007014
Unit: Nm {kgfcm, lbfft}
Remarks
EN01F02127010701007015
Unit: Nm {kgfcm, lbfft}
Remarks
EN01F02127010701007016
Action
Replace
Unit: Nm {kgfcm, lbfft}
Remarks
Need help?
Do you have a question about the S5-LJ05E04A and is the answer not in the manual?