Supply Pump; Injector - Hino S5-LJ05E04A Workshop Manual

Table of Contents

Advertisement

2–8

SUPPLY PUMP

STANDARD VALUE, LIMIT AND ACTION
Inspection item
Resistance between terminals of
suction control valve
Resistance between terminals of
combustion temperature sensor
TIGHTENING TORQUE
Tightening part
Fuel filter drain plug
Bearing holder case mounting bolt
Coupling flange mounting nut
Coupling and supply pump mounting bolts
Pressure feed pipe

INJECTOR

STANDARD VALUE, LIMIT AND ACTION
Inspection item
Insulation resistance of injector
(Between one side of terminal and upper body of
injector)
Resistance value between injector terminals
TIGHTENING TORQUE
Tightening part
Injector clamp mounting bolt
Injection pipe
STANDARD VALUE (J05E)
20C {68F}
–20C {–4F}
20C {68F}
80C {176F}
110C {230F}
(at room temperature)
0.37-0.57  (at 20C {68F})
Standard value
1.6-2.6 
13.84-16.33 k
2.32-2.59 k
0.310-0.326 k
0.1399-0.1435 k
Tightening torque
5-9 {51-91, 3.7-6.6}
28.5 {291, 21}
64 {653, 47}
28.5 {291, 21}
44 {449, 32}
Standard value
10 M or more
Tightening torque
25 {255, 18}
44 {449, 32}
EN01F02127010701003005
Action
Replace
Replace
Replace
Replace
Replace
Unit: Nm {kgfcm, lbfft}
Remarks
EN01F02127010701003006
Action
Replace
Replace
Unit: Nm {kgfcm, lbfft}
Remarks