SHTS021271000123
SHTS021271000124
1.30
1.25
1.20
1.15
1.10
1.00
SHTS021271000125
EXHAUST (J05E)
INSPECTION
INSPECTING DEF CONCENTRATION
1.
CAUTIONS
! CAUTION
There are 3 inspection methods for DEF; DEF analyzer inspection,
pH test paper inspection, and refractive index measurement
inspection. Use one method from three for inspection.
2.
DEF ANALYZER INSPECTION
(1)
Extract the DEF and put a few drops on the DEF analyzer to mea-
sure DEF concentration. Replace the DEF if the measurement
reading exceeds the standard value.
Standard value (%)
3.
PH TEST PAPER INSPECTION
(1)
Extract the DEF and put a few drops on the pH test paper to
check color change. Replace the DEF if the measurement reading
exceeds the standard value.
Concentration (%)
32.5
4.
REFRACTIVE INDEX MEASUREMENT INSPECTION
(1)
Extract the DEF and put a few drops on the refractometer to mea-
sure refractive index. Replace the DEF if the measurement read-
ing exceeds the standard value.
Concentration (%)
32.5
11–73
EN01F02127100402056002
32.5
Standard value (number)
9
Standard value (%)
1.3817 - 1.384