T3: Asr And Inertia Tuning; T4: Ez Tuning - YASKAWA CIPR-GA50C series Technical Manual

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

0 : mV/(rev/min)
1 : mV/(rad/s)
Note:
• When T2-13 = 0, the drive will use E5-24 [PM Back-EMF L-L Vrms (mV/rpm)] and will automatically set E5-09 [PM Back-EMF
Vpeak (mV/(rad/s))] = 0.0.
• When T2-13 = 1, the drive will use E5-09 and will automatically set E5-24 = 0.0.
T2-14: Back-EMF Voltage Constant (Ke)
No.
Name
(Hex.)
T2-14
Back-EMF Voltage
Constant (Ke)
(0737)
T2-15: Pull-In Current Level
No.
Name
(Hex.)
T2-15
Pull-In Current Level
(0756)
If the load inertia is high, increase the setting value.

T3: ASR and Inertia Tuning

T3-00: Control Loop Tuning Selection
No.
Name
(Hex.)
T3-00
Control Loop Tuning
Selection
(1198)
2 : Deceleration Rate Tuning
3 : KEB Tuning

T4: EZ Tuning

Use T4 parameters to input the data necessary for motor parameter Auto-Tuning when A1-02 = 8 [Control
Method Selection = EZ Vector Control]. These two modes are available:
T4-01 Setting
0
Follow the instructions in the setup wizard on the keypad to
manually enter the necessary motor parameters.
1
Do only line-to-line resistance tuning.
*1
When you use a PM motor or a synchronous reluctance motor, it is not necessary to enter the rated frequency. The drive will use the
rated rotation speed and number of motor poles to automatically calculate the rated frequency.
T4-01: EZ Tuning Mode Selection
No.
Name
(Hex.)
T4-01
EZ Tuning Mode Selection
(3130)
0 : Motor Parameter Setting
1 : Line-to-Line Resistance
YASKAWA SIEPC71061753A GA500 Technical Manual
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the motor induced voltage constant (Ke).
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the level of the pull-in current as a percentage of E5-03 [PM Motor Rated Current (FLA)].
Usually it is not necessary to change this setting.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the type of Control Auto-Tuning.
Operational overview
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the type of Auto-Tuning for EZOLV control.
Description
Description
Description
Items input for tuning
• T4-02 [Motor Type Selection]
• T4-03 [Motor Max Revolutions]
• T4-04 [Motor Rated Revolutions]
*1
• T4-05 [Motor Rated Frequency]
• T4-06 [Motor Rated Voltage]
• T4-07 [Motor Rated Current]
• T4-08 [Motor Rated Capacity]
• T4-09 [Number of Poles]
Motor Rated Current
Description
12.12 T: Auto-Tuning
Default
(Range)
Determined by T2-13
(0.0 - 2000.0)
Default
(Range)
30%
(0 - 120%)
Default
(Range)
2
(2, 3)
Items tuned
• E9-01 [Motor Type Selection]
• E9-02 [Maximum Speed]
• E9-03 [Rated Speed]
• E9-04 [Base Frequency]
• E9-05 [Base Voltage]
• E9-06 [Motor Rated Current (FLA)]
• E9-07 [Motor Rated Power]
• E9-08 [Motor Pole Count]
• E9-09 [Motor Rated Slip]
• E9-10 [Motor Line-to-Line Resistance]
E9-10 [Motor Line-to-Line Resistance]
Default
(Range)
0
(0, 1)
12
755

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents