Remove the Control Circuit Board
Remove the front cover and keypad from the drive.
1.
Push the tabs to the left that hold the control board to the drive.
2.
Pull the left side of the control circuit board out first.
Put the Control Circuit Board in a New Drive
Remove the keypad, front cover, and control circuit board of the new drive.
Wire the main circuit terminals of the new drive, then attach the wired control circuit board.
1.
Wire the main circuit terminals.
Note:
To wire terminals +1 and +2, remove the jumper between terminals +1 and +2.
2.
Attach the wired control circuit board to the drive.
Push the control circuit board until the hooks click into place on the drive.
YASKAWA SIEPC71061753A GA500 Technical Manual
Figure 8.20 Unhook the Tabs
Figure 8.21 Remove the Control Circuit Board
Figure 8.22 Wire the Main Circuit Terminals
8.5 Replace the Drive
303