YASKAWA CIPR-GA50C series Technical Manual page 465

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

No.
C1-01
C1-02
C6-01
E1-03
L2-01
L3-04
The drive saves the parameters in
Table 12.13 Parameters Saved as User Parameters with the Air Compressor Preset
User Parameter No.
A2-01
A2-02
A2-03
A2-04
A2-05
A2-06
A2-07
A2-08
A2-09
6 : Crane (Hoist)
The drive automatically sets the parameters in
Note:
Make sure that you do Auto-Tuning after you set A1-06 for a hoist application. Refer to
hoist (elevator) instructions.
No.
A1-02
b1-01
b6-01
b6-02
C1-01
C1-02
C6-01
C6-02
d1-01
d1-02
d1-03
E1-03
H2-01
H2-02
L2-03
L3-04
L4-01
L4-02
L6-01
L6-02
L6-03
YASKAWA SIEPC71061753A GA500 Technical Manual
Acceleration Time 1
Deceleration Time 1
Normal / Heavy Duty Selection
V/f Pattern Selection
Power Loss Ride Through Select
Stall Prevention during Decel
Table 12.13
as User Parameters.
Parameter No. Saved
Table 12.14
Table 12.14 Best Parameter Settings for Hoist Applications
Control Method Selection
Frequency Reference Selection 1
Dwell Reference at Start
Dwell Time at Start
Acceleration Time 1
Deceleration Time 1
Normal / Heavy Duty Selection
Carrier Frequency Selection
Reference 1
Reference 2
Reference 3
V/f Pattern Selection
Term MA,MB,MC Function Selection
Term P1 Function Selection
Minimum Baseblock Time
Stall Prevention during Decel
Speed Agree Detection Level
Speed Agree Detection Width
Torque Detection Selection 1
Torque Detection Level 1
Torque Detection Time 1
12.2 A: Initialization Parameters
Name
b1-01
b1-02
b1-04
C1-01
C1-02
E1-03
E1-07
E1-08
E2-01
for a hoist application.
Notes for Elevator Applications on page 467
Name
Optimal Value
5.0 s
5.0 s
0: Heavy Duty Rating
F: Custom
1: Enabled for L2-02 Time
1: General Purpose
Name
Frequency Reference Selection 1
Run Command Selection 1
Reverse Operation Selection
Acceleration Time 1
Deceleration Time 1
V/f Pattern Selection
Mid Point A Frequency
Mid Point A Voltage
Motor Rated Current (FLA)
Optimal Value
2: Open Loop Vector
0: Keypad
3.0 Hz
0.3 s
3.0 s
3.0 s
0: Heavy Duty Rating
2: 5.0 kHz (4.0 kHz for AOLV/PM)
6.00 Hz
30.00 Hz
50.00 Hz
F: Custom
5: Frequency Detection 2
37: During Frequency Output
0.3 s
0: Disabled
2.0 Hz
0.0 Hz
8: UL @ RUN - Fault
2%
0.5 s
for
12
465