H4: Analog Outputs - YASKAWA CIPR-GA50C series Technical Manual

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

12.8 H: Terminal Function Selection
1F: Not Used
Setting Value
Function
1F
Not Used
When you set a terminal that you do not use to 1F, you can use the signal that is input to that terminal as the PLC
analog signal input from MEMOBUS/Modbus communications or the communication option. This input signal
does not have an effect on drive operation. This signal functions the same as F (Through Mode).
30: DWEZ Analog Input 1
Setting Value
Function
30
DWEZ Analog Input 1
31: DWEZ Analog Input 2
Setting Value
Function
31
DWEZ Analog Input 2

H4: Analog Outputs

H4 parameters set the drive analog monitors. These parameters select monitor parameters, adjust gain and bias,
and select output signal levels.
Calibrate Meters Connected to MFAO Terminal AM
Use these parameters to calibrate meters connected to terminal AM:
• H4-02 [Terminal AM Analog Output Gain]
• H4-03 [Terminal AM Analog Output Bias]
Set these parameters where the output voltage of 10 V and output current of 20 mA are 100% of the signal level.
Use jumper switch S5 and parameter H4-07 [Terminal AM Signal Level Select] to set the voltage output and
current output.
No.
H4-02
Terminal AM Analog Output Gain
H4-03
Terminal AM Analog Output Bias
H4-07
Terminal AM Signal Level Select
Figure 12.97
and
Figure 12.98
For example, when the parameter value set to analog output is 0, and a 3 V signal is to be output to terminal AM,
set H4-03 [AM Analog Output Bias] = 30%.
652
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Use this setting for unused terminals or to use terminals in through mode.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Use with DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Use with DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
Name
show the gain and bias.
Figure 12.97 Analog Output Gain/Bias Configuration Example 1
Description
Description
Description
Range
-999.9 - +999.9%
-999.9 - +999.9%
0: 0 +10 VDC
2: 4-20 mA
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
100.0%
0.0%
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents