T2-05: PM Motor Rated Voltage
No.
Name
(Hex.)
T2-05
PM Motor Rated Voltage
(0732)
T2-06: PM Motor Rated Current
No.
Name
(Hex.)
T2-06
PM Motor Rated Current
(0733)
T2-07: PM Motor Base Frequency
No.
Name
(Hex.)
T2-07
PM Motor Base Frequency
(0753)
T2-08: Number of PM Motor Poles
No.
Name
(Hex.)
T2-08
Number of PM Motor Poles
(0734)
T2-09: PM Motor Base Speed
No.
Name
(Hex.)
T2-09
PM Motor Base Speed
(0731)
T2-10: PM Motor Stator Resistance
No.
Name
(Hex.)
T2-10
PM Motor Stator Resistance
(0754)
Note:
This parameter does not set line-to-line resistance.
T2-11: PM Motor d-Axis Inductance
No.
Name
(Hex.)
T2-11
PM Motor d-Axis
Inductance
(0735)
T2-12: PM Motor q-Axis Inductance
No.
Name
(Hex.)
T2-12
PM Motor q-Axis
Inductance
(0736)
T2-13: Back-EMF Units Selection
No.
Name
(Hex.)
T2-13
Back-EMF Units Selection
(0755)
754
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the rated voltage (V) of the motor.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the rated current (A) of the motor.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the base frequency (Hz) of the motor.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the number of motor poles.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the motor base speed (min
-1
(r/min)).
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the stator resistance for each motor phase.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the d-axis inductance of the motor on a per phase basis.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the q-Axis inductance of the motor on a per phase basis.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the units that the drive uses to set the induced voltage constant.
Description
Description
Description
Description
Description
Description
Description
Description
Description
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
(Range)
200 V Class: 200.0 V, 400
V: 400.0 V
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
Default
(Range)
Determined by o2-04
(10% to 200% of the drive
rated current)
Default
(Range)
87.5 Hz
(0.0 - 590.0 Hz)
Default
(Range)
6
(2 - 48)
Default
(Range)
1750 min
-1
(r/min)
(0 - 34500 min
-1
(r/min))
Default
(Range)
Determined by T2-02
(0.000 - 65.000 Ω)
Default
(Range)
Determined by T2-02
(0.00 - 600.00 mH)
Default
(Range)
Determined by T2-02
(0.00 - 600.00 mH)
Default
(Range)
1
(0, 1)