YASKAWA CIPR-GA50C series Technical Manual page 414

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

11.17 U: Monitors
No.
Name
(Hex.)
U1-11
Output Terminal Status
(004A)
U1-12
Drive Status
(004B)
U1-13
Terminal A1 Level
(004E)
U1-14
Terminal A2 Level
(004F)
U1-16
SFS Output Frequency
(0053)
U1-18
oPE Fault Parameter
(0061)
U1-19
MEMOBUS/Modbus Error
Code
(0066)
U1-24
Input Pulse Monitor
(007D)
U1-25
Software number
(004D)
U1-26
SoftwareNumber ROM
(005B)
414
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Shows the status of the MFDO terminal where
For example, U1-11 shows
bit0 : Terminal MA/MB-MC
bit1 : Terminal P1-C1
bit2 : Terminal P2-C2
bit3 : Not used (normal value of [ ]).
bit4 : Not used (normal value of [ ]).
bit5 : Not used (normal value of [ ]).
bit6 : Not used (normal value of [ ]).
bit7 : Not used (normal value of [ ]).
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Shows drive status where
= ON and
For example, U1-12 shows
bit0 : During Run
bit1 : During zero-speed
bit2 : During reverse
bit3 : During fault reset signal input
bit4 : During speed agreement
bit5 : Drive Ready
bit6 : During minor fault detection
bit7 : During fault detection
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Shows the signal level of terminal A1.
Unit: 0.1%
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Shows the signal level of terminal A2.
Unit: 0.1%
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Shows the output frequency after soft start. Shows the frequency with acceleration and
deceleration times and S-curves. Parameter o1-03 [Keypad Display Unit Selection] sets the
display units.
Unit: 0.01 Hz
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Shows the parameter number that caused the oPE02 [Parameter Range Setting Error] or oPE08
[Parameter Selection Error].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Shows the contents of the MEMOBUS/Modbus communication error where
"no error".
For example, U1-19 shows
bit0 : CRC Error
bit1 : Data Length Error
bit2 : Not used (normal value of [ ]).
bit3 : Parity Error
bit4 : Overrun Error
bit5 : Framing Error
bit6 : Timed Out
bit7 : Not used (normal value of [ ]).
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Shows the frequency to pulse train input terminal RP.
Unit: 1 Hz
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Shows the ID.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Shows the ROM ID.
Description
= (ON) and
= (OFF).
when terminals MA and P2 are ON.
= OFF.
during run with the Reverse Run command.
="error" and
when the drive detects a CRC error.
YASKAWA SIEPC71061753A GA500 Technical Manual
MFAO Signal Level
No signal output available
No signal output available
10 V = 100% (-10 V to +10
V)
10 V = 100% (-10 V to +10
V)
10 V = Maximum
frequency (-10 V to +10 V)
No signal output available
No signal output available
=
Determined by H6-02
No signal output available
No signal output available

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents