No.
Name
(Hex.)
F7-15
Communication Speed
Selection
(03F3)
F7-16
Timeout Value
(03F4)
F7-17
EtherNet/IP Speed
Scaling Factor
(03F5)
F7-18
EtherNet/IP Current
Scale Factor
(03F6)
F7-19
EtherNet/IP Torque
Scale Factor
(03F7)
F7-20
EtherNet/IP Power
Scaling Factor
(03F8)
F7-21
EtherNet/IP Voltage
Scale Factor
(03F9)
F7-22
EtherNet/IP Time
Scaling
(03FA)
F7-23 - F7-27
Dynamic Out Param 1 to
10 for CommCard
(03FB - 03FF)
F7-28- F7-32
(0370 - 0374)
F7-33 - F7-42
Dynamic In Param 1 to
10 for CommCard
(0375 - 037E)
F7-60
PZD1 Write (Control
Word)
(0780)
F7-61
PZD2 Write (Frequency
Reference)
(0781)
F7-62
PZD3 Write
(0782)
F7-63
PZD4 Write
(0783)
F7-64
PZD5 Write
(0784)
F7-65
PZD6 Write
(0785)
F7-66
PZD7 Write
(0786)
F7-67
PZD8 Write
(0787)
F7-68
PZD9 Write
(0788)
F7-69
PZD10 Write
(0789)
F7-70
PZD1 Read (Status
Word)
(078A)
YASKAWA SIEPC71061753A GA500 Technical Manual
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the communications speed.
10 : 10/10 Mbps
100 : 100/100 Mbps
101 : 10/100 Mbps
102 : 100/10 Mbps
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the detection time for a communications timeout.
Note:
Set this parameter to 0.0 to disable the connection timeout function.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the scaling factor for the speed monitor in the EtherNet/IP Class ID 2AH Object.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the scaling factor for the output current monitor in the EtherNet/IP Class ID 2AH
Object.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the scaling factor for the torque monitor in the EtherNet/IP Class ID 2AH Object.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the scaling factor for the power monitor in the EtherNet/IP Class ID 2AH Object.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the scaling factor for the voltage monitor in the EtherNet/IP Class ID 2AH Object.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the scaling factor for the time monitor in the EtherNet/IP Class ID 2AH Object.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets Output Assembly 116. The drive writes the values from Output Assembly 116 to
the MEMOBUS/Modbus address register that is stored for each parameter. The drive
will not write the values from Output Assembly 116 to the registers when the
MEMOBUS/Modbus address is 0.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets Input Assembly 166. The drive sends the values from the MEMOBUS/Modbus
address registers stored for each parameter to Input Assembly 166. The drive returns the
default register value for the option card when the MEMOBUS/Modbus address is 0
and the value sent to Input Assembly 166 is not defined.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the MEMOBUS/Modbus address for PZD1 (PPO output). PZD1 (PPO output)
functions as the STW when F7-60 = 0, 1, or 2.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the MEMOBUS/Modbus address for PZD2 (PPO output). PZD2 (PPO output)
functions as the HSW when F7-61 = 0, 1, or 2.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the MEMOBUS/Modbus address for PZD3 (PPO output). A value of 0, 1, or 2 will
disable the PZD3 (PPO output) write operation to the MEMOBUS/Modbus register.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the MEMOBUS/Modbus address for PZD4 (PPO output). A value of 0, 1, or 2 will
disable the PZD4 (PPO output) write operation to the MEMOBUS/Modbus register.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the MEMOBUS/Modbus address for PZD5 (PPO output). A value of 0, 1, or 2 will
disable the PZD5 (PPO output) write operation to the MEMOBUS/Modbus register.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the MEMOBUS/Modbus address for PZD6 (PPO output). A value of 0, 1, or 2 will
disable the PZD6 (PPO output) write operation to the MEMOBUS/Modbus register.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the MEMOBUS/Modbus address for PZD7 (PPO output). A value of 0, 1, or 2 will
disable the PZD7 (PPO output) write operation to the MEMOBUS/Modbus register.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the MEMOBUS/Modbus address for PZD8 (PPO output). A value of 0, 1, or 2 will
disable the PZD8 (PPO output) write operation to the MEMOBUS/Modbus register.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the MEMOBUS/Modbus address for PZD9 (PPO output). A value of 0, 1, or 2 will
disable the PZD9 (PPO output) write operation to the MEMOBUS/Modbus register.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the MEMOBUS/Modbus address for PZD10 (PPO output). A value of 0, 1, or 2
will disable the PZD10 (PPO output) write operation to the MEMOBUS/Modbus
register.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the MEMOBUS/Modbus address for PZD1 (PPO Read). PZD1 (PPO input)
functions as the ZSW when F7-70 = 0.
11.9 F: Options
Default
Ref.
(Range)
10
594
(10, 100 - 102)
0.0 s
595
(0.0 - 30.0 s)
0
595
(-15 - +15)
0
595
(-15 - +15)
0
595
(-15 - +15)
0
595
(-15 - +15)
0
595
(-15 - +15)
0
595
(-15 - +15)
0
595
0
596
0
596
0
596
0
596
0
596
0
596
0
596
0
596
0
597
0
597
0
597
0
597
367