YASKAWA CIPR-GA50C series Technical Manual page 612

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

12.8 H: Terminal Function Selection
Signal Input Method from
Peripheral Devices
Setting
N.O.
25
-
26
x
27
-
28
x
29
-
2A
x
2B
-
2C
x
2D
-
2E
x
2F
-
*1
Set the terminal to N.O. (detects external fault when switched ON) or N.C. (detects external fault when switched OFF).
*2
Set the drive to always detect each fault or to detect only during run.
30: PID Integrator Reset
Setting Value
Function
30
PID Integrator Reset
Note:
Refer to "PID control block diagram" for more information.
31: PID Integrator Hold
Setting Value
Function
31
PID Integrator Hold
When you turn off the input terminal, PID control restarts the integral.
Note:
Refer to "PID control block diagram" for more information.
32: Multi-Step Speed Reference 4
Setting Value
Function
32
Multi-Step Speed Reference
4
Note:
Refer to "Setting Procedures for Multi-step Speed Operation" in "d: Reference Settings" for more information.
34: PID Soft Starter Disable
Setting Value
Function
34
PID Soft Starter Disable
ON : Disabled
Disables b5-17 [PID Accel/Decel Time].
OFF : Enabled
Enables b5-17 [PID Accel/Decel Time].
Note:
Refer to "PID control block diagram" for more information.
612
External Fault Detection Method
*1
*2
Detected
Always
N.C.
during RUN
Detected
x
x
-
-
x
-
-
x
x
x
-
-
x
-
-
x
x
x
-
-
x
-
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the command to reset and hold the PID control integral to 0 when the terminal is ON.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the command to hold the integral value of the PID control while the terminal is activated.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Uses speed references d1-01 to d1-16 to set a multi-step speed reference.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the PID soft starter function.
Ramp to Stop
Coast to Stop
(Fault)
Only
-
-
x
-
x
-
-
-
-
-
x
-
x
-
-
-
-
-
x
-
x
-
Description
Description
Description
Description
YASKAWA SIEPC71061753A GA500 Technical Manual
Stopping Method
Continuous
Fast Stop
(Fault)
(Fault)
(Alarm Only)
x
-
x
-
x
-
-
x
-
x
-
x
-
x
-
-
-
-
-
-
-
-
Operation
-
-
-
-
-
-
-
x
x
x
x

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents