Auto-Tuning For Pm Motors - YASKAWA CIPR-GA50C series Technical Manual

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

Input Data
Parameter
Motor Rated Slip
Frequency
Motor Iron Loss
*3
Test Mode Selection
No-Load Voltage
*1
Shows 0 Hz as the default value. If you do not know the Motor Rated Slip Frequency, keep the setting at 0 Hz.
*2
Input this value when A1-02 = 0 [Control Method Selection = V/f].
*3
If T1-12 = 1 [Test Mode Selection = Yes], when you run the motor in Drive Mode for the first time after Auto-Tuning, the drive will
automatically set E2-02 [Motor Rated Slip] and E2-03 [Motor No-Load Current].
*4
Input this value when T1-10 [Motor Rated Slip Frequency] = 0 Hz.
*5
Set the same value to No-Load Voltage as T1-03 [Motor Rated Voltage] to get the same characteristics using Yaskawa 1000-Series
drives or other legacy models.

Auto-Tuning for PM Motors

This section gives information about Auto-Tuning for PM motors. Auto-Tuning sets motor parameters E1-xx and
E5-xx.
Mode
Manual Entry w/ Motor Data Sheet
PM Stationary Auto-Tuning
PM Stationary Auto-Tuning for Stator
Resistance
PM Motor Code Selection
High Frequency Injection
Input Data for PM Motor Auto-Tuning
To do Auto-Tuning, input data for the items in
Tuning, prepare the motor test report or record the information on the motor nameplate as a reference.
YASKAWA SIEPC71061753A GA500 Technical Manual
Unit
T1-10
Hz
T1-11
W
T1-12
-
T1-13
V
Table 4.9 Auto-Tuning for PM Motors
Parameter Settings
Application Conditions and Benefits
• When the information from the motor test report or motor
nameplate is available.
T2-01 = 0
• Rotational/Stationary Auto-Tuning that energizes the motor
is not done. Manually input the necessary motor
parameters.
• When the information from the motor test report or motor
nameplate is not available.
Note:
T2-01 = 1
With Stationary Auto-Tuning, the energized drive stays
stopped for approximately 1 minute. During this time, the
drive automatically measures the necessary motor
parameters.
• After Auto-Tuning, the wiring distance between the drive
and motor changed by 50 m (164 ft) or more.
T2-01 = 2
• When the motor output and drive capacity are different.
• When the information from the motor test report or motor
nameplate is not available.
• When you can decouple the motor and load and the motor
T2-01 = 4
can rotate freely while Auto-Tuning.
• The drive will automatically set the values measured during
Auto-Tuning to the motor parameters.
• Automatically sets the control parameters that are
necessary to set n8-35 = 1 [Initial Pole Detection Method
= High Frequency Injection] or n8-57 = 1 [HFI Overlap
Selection = Enabled].
• Applicable to IPM motors only.
• Do Auto-Tuning with the motor connected to the drive.
T2-01 = 5
Note:
When you set n8-35 = 1 or n8-57 = 1, do High Frequency
Injection Auto-Tuning. Set the data on the motor
nameplate to the drive before you do High Frequency
Injection Auto-Tuning. In High Frequency Injection Auto-
Tuning, the drive energizes the stopped motor and
automatically adjusts the parameters.
Table
Stationary Auto-Tuning
Rotational Auto-Tuning
(0)
-
*2
x
-
*5
x
4.10 and
Table 4.11
that have an "x". Before starting Auto-
4.9 Auto-Tuning
Auto-Tuning Mode
(T1-01 Setting)
Stationary Line-Line
1
Resistance
(1)
(2)
*1
x
-
*4
x
*5
x
Applicable Control Method
(A1-02 Setting)
OLV/PM
AOLV/PM
(5)
x
x
x
x
x
-
-
-
-
(6)
x
x
x
x
4
x
135