YASKAWA CIPR-GA50C series Technical Manual page 567

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

• When you use A1-03 [Initialize Parameters] to initialize the drive, the drive will reset the manually set values
for E3-04 to E3-13 [Motor 2 Base Voltage] to default values.
E3-01: Motor 2 Control Mode Selection
No.
Name
(Hex.)
E3-01
Motor 2 Control Mode
Selection
(0319)
Note:
• When you change this setting, the drive will set all parameters that are dependent on E3-01 to their default settings.
• Parameter L1-01 [Motor Overload (oL1) Protection] sets the protection operation of oL1 [Motor Overload] the same as Motor 1.
• When you use parameter A1-03 [Initialize Parameters] to initialize the drive, this parameter is not reset.
0 : V/f Control
2 : Open Loop Vector
E3-04: Motor 2 Maximum Output Frequency
No.
Name
(Hex.)
E3-04
Motor 2 Maximum Output
Frequency
(031A)
E3-05: Motor 2 Maximum Output Voltage
No.
Name
(Hex.)
E3-05
Motor 2 Maximum Output
Voltage
(031B)
E3-06: Motor 2 Base Frequency
No.
Name
(Hex.)
E3-06
Motor 2 Base Frequency
(031C)
E3-07: Motor 2 Mid Point A Frequency
No.
Name
(Hex.)
E3-07
Motor 2 Mid Point A
Frequency
(031D)
E3-08: Motor 2 Mid Point A Voltage
No.
Name
(Hex.)
E3-08
Motor 2 Mid Point A
Voltage
(031E)
E3-09: Motor 2 Minimum Output Frequency
No.
Name
(Hex.)
E3-09
Motor 2 Minimum Output
Frequency
(031F)
YASKAWA SIEPC71061753A GA500 Technical Manual
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the control method for motor 2.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Set the maximum output frequency for the motor 2 V/f pattern.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the maximum output voltage for the motor 2 V/f pattern.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the base frequency for the motor 2 V/f pattern.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets a middle output frequency for the motor 2 V/f pattern.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets a middle output voltage for the motor 2 V/f pattern.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the minimum output frequency for the motor 2 V/f pattern.
Description
Description
Description
Description
Description
Description
Description
12.6 E: Motor Parameters
Default
(Range)
0
(0, 2)
Default
(Range)
Determined by E3-01
(40.0 - 590.0 Hz)
Default
(Range)
Determined by E3-01
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
Default
(Range)
Determined by E3-01
(0.0 - E3-04)
Default
(Range)
Determined by E3-01
(0.0 - E3-04)
Default
(Range)
Determined by E3-01
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
Default
(Range)
Determined by E3-01
(0.0 - E3-04)
567