12.8 H: Terminal Function Selection
H6-03: Terminal RP Function Gain
No.
Name
(Hex.)
H6-03
Terminal RP Function Gain
(042E)
RUN
H6-04: Terminal RP Function Bias
No.
Name
(Hex.)
H6-04
Terminal RP Function Bias
(042F)
RUN
H6-05: Terminal RP Filter Time
No.
Name
(Hex.)
H6-05
Terminal RP Filter Time
(0430)
RUN
H6-06: Terminal MP Monitor Selection
No.
Name
(Hex.)
H6-06
Terminal MP Monitor
Selection
(0431)
RUN
Note:
To use in through mode or when terminal MP is not used, set this parameter to 000 or 031.
When you use the pulse train monitor, make sure that you connect peripheral devices as specified by these load
conditions:
Incorrect connections can make the characteristics not sufficient or cause mechanical damage.
• Use the pulse train monitor as the sourcing output.
• Use the pulse train monitor as the sinking input
External Power Supply (V)
Sinking current (mA)
660
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the gain used when the function in H6-01 [Terminal RP Pulse Train Function] is input to
terminal RP.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the bias used when the function in H6-01 [Terminal RP Pulse Train Function] is input to
terminal RP. Sets a value at the time when the pulse train is 0 Hz.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the time constant for the pulse train input primary delay filters.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets a function for pulse train monitor output terminal MP. Sets the "x-xx" part of the Ux-xx
monitor.
Output Voltage
VRL(V)
5 V or more
8 V or more
10 V or more
Figure 12.102 Circuit Diagram When Used as the Sourcing Output
Description
Description
Description
Description
Load Impedance (kΩ)
1.5 kΩ or more
4.0 kΩ or more
10 kΩ or more
12 VDC ± 10%, 15 VDC ± 10%
16 mA or less
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
(Range)
100.0%
(0.0 - 1000.0%)
Default
(Range)
0.0%
(-100.0 - 100.0%)
Default
(Range)
0.10 s
(0.00 - 2.00 s)
Default
(Range)
102
(000, 031, 101, 102, 105,
116, 501, 502, 801 - 809,
821 - 825, 831 - 839, 851 -
855)