11.18 Parameters that Change from the Default Settings with A1-02 [Control Method Selection]

11.18 Parameters that Change from the Default Settings with
A1-02 [Control Method Selection]
The values for the parameters in these tables depend on the values for parameter A1-02. When you change the
setting for A1-02, the default settings will change.
No.
DC Injection/Zero
b2-01
SpeedThreshold
DC Inject Braking Time at
b2-04
Stop
Speed Search at Start
b3-01

Selection

SpeedSearch Deactivation
b3-02
Current
Speed Estimation ACR P
b3-08
Gain
Speed Estimation ACR I
b3-09
Time
Bi-directional Speed
b3-14
Search
PID Sleep Function Start
b5-15
Level
b6-01
Dwell Reference at Start
b6-03
Dwell Reference at Stop
b8-02
Energy Saving Gain
b8-03
Energy Saving Filter Time
E-Save Search Injection
b8-19
Freq
Accel/Decel Time
C1-11
Switchover Freq
S-Curve Time @ Start of
C2-01
Accel
C3-01
Slip Compensation Gain
Slip Compensation Delay
C3-02
Time
C4-01
Torque Compensation Gain
Torque Compensation
C4-02
Delay Time
C5-01
ASR Proportional Gain 1
C5-02
ASR Integral Time 1
C5-03
ASR Proportional Gain 2
C5-04
ASR Integral Time 2
C5-06
ASR Delay Time
ASR Gain Switchover
C5-07
Frequency
Carrier Frequency
C6-02
Selection
d3-01
Jump Frequency 1
d3-02
Jump Frequency 2
d3-03
Jump Frequency 3
d3-04
Jump Frequency Width
Maximum Output
E1-04
Frequency
E1-05
Maximum Output Voltage
E1-06
Base Frequency
YASKAWA SIEPC71061753A GA500 Technical Manual
Table 11.1 A1-02 = 0, 2 [V/f, OLV]
Name
Range
0.0 - 10.0
0.00 - 10.00
0 - 1
0 - 200
0.00 - 6.00
0.0 - 1000.0
0 - 1
0.0 - 400.0
0.0 - 400.0
0.0 - 400.0
0.0 - 10.0
0.00 - 10.00
10 - 300
0.0 - 400.0
0.00 - 10.00
0.0 - 2.5
0 - 10000
0.00 - 2.50
0 - 10000
0.00 - 300.00
0.000 - 60.000
0.00 - 300.00
0.000 - 10.000
0.000 - 0.500
0.0 - 400.0
1 - F
0.0 - 400.0
0.0 - 400.0
0.0 - 400.0
0.0 - 20.0
*2 *3
40.0 - 400.0
*5
0.0 - 255.0
*3
0.0 - 400.0
Control Method (A1-02 Setting)
Unit
V/f
(0)
0.1 Hz
0.5
0.01 s
0.50
1
0
1%
120
*1
0.01
0.50
0.1 ms
2.0
1
0
0.1 Hz
0.0
0.1 Hz
0.0
0.1 Hz
0.0
0.1
-
0.01 s
-
1 Hz
100
0.1 Hz
0.0
0.01 s
0.20
0.1
0.0
1 ms
2000
0.01
1.00
1 ms
200
0.01
-
0.001 s
-
0.01
-
0.001 s
-
0.001 s
-
0.1 Hz
0.0Hz
*2
1
1
0.1 Hz
0.0
0.1 Hz
0.0
0.1 Hz
0.0
0.1 Hz
1.0
*4
0.1 Hz
60.0
*4
0.1 V
200.0
*4
0.1 Hz
60.0
OLV
(2)
0.5
0.50
0
100
*1
0.50
2.0
0
0.0
0.0
0.0
0.7
0.50
100
0.0
0.20
1.0
200
1.00
20
-
-
-
-
-
0.0Hz
*2
1
0.0
0.0
0.0
1.0
60.0
11
200.0
60.0
425