12.2 A: Initialization Parameters
No.
L8-05
L8-07
L8-38
L8-41
The drive saves the parameters in
Table 12.15 Parameters Saved as User Parameters with the Hoist Preset
User Parameter No.
A2-01
A2-02
A2-03
A2-04
A2-05
A2-06
A2-07
A2-08
A2-09
A2-10
A2-11
A2-12
A2-13
A2-14
A2-15
A2-16
7 : Crane (Traveling)
The drive automatically sets the parameters in
No.
A1-02
b1-01
C1-01
C1-02
C6-01
C6-02
d1-01
d1-02
d1-03
H1-05
H1-06
H2-01
H2-02
L3-04
L8-05
L8-07
L8-38
L8-41
466
Input Phase Loss Protection Sel
Output Phase Loss Protection Sel
Carrier Frequency Reduction
High Current Alarm Selection
Table 12.15
as User Parameters.
Parameter No. Saved
Table 12.16
Table 12.16 Optimal Settings for Traveling Applications
Control Method Selection
Frequency Reference Selection 1
Acceleration Time 1
Deceleration Time 1
Normal / Heavy Duty Selection
Carrier Frequency Selection
Reference 1
Reference 2
Reference 3
Terminal S5 Function Selection
Terminal S6 Function Selection
Term MA,MB,MC Function Selection
Term P1 Function Selection
Stall Prevention during Decel
Input Phase Loss Protection Sel
Output Phase Loss Protection Sel
Carrier Frequency Reduction
High Current Alarm Selection
Name
A1-02
b1-01
b6-01
b6-02
C1-01
C1-02
C6-02
d1-01
d1-02
d1-03
E1-08
H2-01
L1-01
L4-01
L6-02
L6-03
for a traveling application.
Name
YASKAWA SIEPC71061753A GA500 Technical Manual
Optimal Value
1: Enabled
1: Fault when One Phase is Lost
1: Enabled below 6 Hz
1: Enabled
Name
Control Method Selection
Frequency Reference Selection 1
Dwell Reference at Start
Dwell Time at Start
Acceleration Time 1
Deceleration Time 1
Carrier Frequency Selection
Reference 1
Reference 2
Reference 3
Mid Point A Voltage
Term MA,MB,MC Function Selection
Motor Overload (oL1) Protection
Speed Agree Detection Level
Torque Detection Level 1
Torque Detection Time 1
Optimal Value
0: V/f Control
0: Keypad
3.0 s
3.0 s
0: Heavy Duty Rating
2: 5.0 kHz (4.0 kHz for AOLV/PM)
6.00 Hz
30.00 Hz
50.00 Hz
3: Multi-Step Speed Reference 1
4: Multi-Step Speed Reference 2
37: During Frequency Output
37: During Frequency Output
0: Disabled
1: Enabled
1: Fault when One Phase is Lost
1: Enabled below 6 Hz
1: Enabled