YASKAWA CIPR-GA50C series Technical Manual page 619

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

The drive will short circuit the three phases of a PM motor to cause braking torque in the spinning motor.
Note:
• When A1-02 = 8 [Control Method Selection = EZOLV], this function is available only when you use a PM motor.
• Refer to "b2: DC Injection Braking and Short Circuit Braking" for more information.
ON : Short Circuit Braking is enabled.
OFF : Normal operation
7D: Short Circuit Braking (N.C.)
Setting Value
Function
7D
Short Circuit Braking
(N.C.)
The drive will short circuit the three phases of a PM motor to cause braking torque in the spinning motor.
Note:
• When A1-02 = 8 [Control Method Selection = EZOLV], this function is available only when you use a PM motor.
• Refer to "b2: DC Injection Braking and Short Circuit Braking" for more information.
ON : Normal operation
OFF : Short Circuit Braking is enabled.
7E: Reverse Rotation Identifier
Setting Value
Function
7E
Reverse Rotation Identifier
ON : Reverse run
The drive knows that the motor is rotating in the reverse direction.
OFF : Forward run
The drive knows that the motor is rotating in the forward direction.
7F: PID Bi-Directional Enable
Setting Value
Function
7F
PID Bi-Directional Enable
ON : Enabled
OFF : Disabled
90 to 96: DWEZ Digital Inputs 1 to 7
Setting Value
Function
90 - 96
DWEZ Digital Inputs 1 to 7
Note:
You cannot set values 90 to 96 for inverse output.
9F: DWEZ Disable
Setting Value
Function
9F
DWEZ Disable
Note:
Set A1-07 = 2 [DriveWorksEZ Function Selection = Digital input] to use this function.
ON : Disabled
OFF : Enabled
YASKAWA SIEPC71061753A GA500 Technical Manual
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets operation of Short Circuit Braking (N.C.).
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Set the motor rotation direction when you use Simple Closed Loop V/f Control method.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets operation of the PID Bi-Directional function.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets digital inputs used with DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets operation of the DriveWorksEZ program saved in the drive.
12.8 H: Terminal Function Selection
Description
Description
Description
Description
Description
12
619