YASKAWA CIPR-GA50C series Technical Manual page 562

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

12.6 E: Motor Parameters
HD : 2001 - 2021, B001 - B018, 4001 - 4012
ND : 2001 - 2018, B001 - B012, 4001 - 4009
E : Const Trq, 60 Hz base, 180 Hz max
Use this constant output pattern to rotate motors at more than 60 Hz. Output voltage is constant when you operate
at more than 60 Hz.
Note:
The voltage values in the figures are for 200 V class drives. Multiply the values by 2 for 400 V class drives.
HD : 2001 - 2021, B001 - B018, 4001 - 4012
ND : 2001 - 2018, B001 - B012, 4001 - 4009
F : V/f Pattern Selection
Set E1-04 to E1-13 [V/f Pattern for Motor 1] to set the values for this custom pattern.
The default settings are the same as Setting Value 0 [Const Trq, 50 Hz base, 60Hz max].
E1-04: Maximum Output Frequency
No.
Name
(Hex.)
E1-04
Maximum Output
Frequency
(0303)
E1-05: Maximum Output Voltage
No.
Name
(Hex.)
E1-05
Maximum Output Voltage
(0304)
E1-06: Base Frequency
No.
Name
(Hex.)
E1-06
Base Frequency
(0305)
E1-07: Mid Point A Frequency
No.
Name
(Hex.)
E1-07
Mid Point A Frequency
(0306)
562
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the maximum output frequency for the V/f pattern.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the maximum output voltage for the V/f pattern.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the base frequency for the V/f pattern.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets a middle output frequency for the V/f pattern.
HD : 2030 - 2082, 4018 - 4060
ND : 2021 - 2082, 4012 - 4060
HD : 2030 - 2082, 4018 - 4060
ND : 2021 - 2082, 4012 - 4060
Description
Description
Description
Description
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
(Range)
Determined by A1-02 and
E5-01
(Determined by A1-02 and
E5-01)
Default
(Range)
200.0
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
Default
(Range)
Determined by A1-02 and
E5-01
(0.0 - E1-04)
Default
(Range)
Determined by A1-02
(0.0 - E1-04)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents