H2: Digital Outputs

H2 parameters set the MFDO terminal functions.
H2-01 to H2-03 Terminal MA/MB-MC, P1-C1, P2-C2 Function Selection
The drive has four MFDO terminals.
No.
H2-01
H2-02
H2-03
Refer to
Table 12.61
to set H2-xx [MFDO Function Select].
Setting Value
0
During Run
1
Zero Speed
2
Speed Agree 1
3
User-Set Speed Agree 1
4
Frequency Detection 1
5
Frequency Detection 2
6
Drive Ready
7
DC Bus Undervoltage
8
During Baseblock (N.O.)
9
Frequency Reference from Keypad
A
Run Command Source
B
Torque Detection 1 (N.O.)
C
Frequency Reference Loss
D
Braking Resistor Fault
E
Fault
*1
F
Not Used
10
Alarm
11
Fault Reset Command Active
12
Timer Output
13
Speed Agree 2
14
User-Set Speed Agree 2
15
Frequency Detection 3
16
Frequency Detection 4
17
Torque Detection 1 (N.C.)
18
Torque Detection 2 (N.O.)
19
Torque Detection 2 (N.C.)
620
Sets the function of the selected MFDI to operate inversely. To select the function, enter "1xx", where the "xx" is the function
setting value.
Table 12.55
Table 12.60
shows the default function settings for the terminals.
Table 12.60 MFDO Terminals Default Function Settings
Name
Term MA/MB-MC Function Selection
(Contact)
Term P1-C1 Function Selection
Term P2-C2 Function Selection
Table 12.61 MFDO Setting Values
Function
Reference
629
629
629
630
630
631
631
631
632
632
632
632
632
632
632
633
633
633
633
633
633
634
634
635
635
635
Description
for more information.
Default
0
1
2
Setting Value
1A
During reverse
1B
During Baseblock (N.C.)
1C
Motor 2 Selection
1E
Executing Auto-Restart
1F
Motor Overload Alarm (oL1)
20
Drive Overheat Pre-Alarm (oH)
21
Safety Monitor Output Status
22
Mechanical Weakening Detection
2F
Maintenance Notification
30
During Torque Limit
37
During Frequency Output
38
Drive Enabled
39
Watt Hour Pulse Output
3C
LOCAL Control Selected
3D
During Speed Search
3E
PID Feedback Low
3F
PID Feedback High
4A
During KEB Ride-Thru
4B
During Short Circuit Braking
4C
During Fast Stop
4D
oH Pre-Alarm Time Limit
4E
Braking Transistor Fault (rr)
4F
Braking Resistor Overheat (rH)
61
Pole Position Detection Complete
62
Modbus Reg 1 Status Satisfied
63
Modbus Reg 2 Status Satisfied
YASKAWA SIEPC71061753A GA500 Technical Manual
Function
During Run
Zero Speed
Speed Agree 1
Function
Reference
636
636
636
636
636
637
637
637
637
637
637
638
638
638
638
638
639
639
639
639
639
639
639
640
640
640

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents